Technical specifications
Technical specifications
Physical dimension
Power requirements
Power requirements ISE unit
Measurement principles
Environmental conditions
Throughput
Samples
NOTICE
Every effort has been made to ensure that all the information contained in these specifica-
tions is correct at the time of printing. However, Roche Diagnostics reserves the right to
make any changes necessary without notice as part of ongoing product development.
Width
720 mm
Depth
550 mm
Height
480 mm
Weight
Approximately 35 kg
Line voltage
100-125 V and 200-240 V (-15%, +10%)
Line frequency
50 Hz (±5%) and 60 Hz (±5%)
Power consumption
250 VA
Insulation coordination
Installation category II (IEC 61010-1)
Main fuse
T6. 3 A H 250 V
Low voltage fuses
T3. 15 A L 250 V
Battery
Lithium 3.6 V 2.3 Ah SL-360/S
Line voltage
100-240 V (±10%)
Line frequency
50 Hz (±5%) and 60 Hz (±5%)
Supply voltage
19-24 V DC, Min. 2A
Power consumption
70 VA
Insulation coordination
Installation category II (IEC 61010-1)
Absorbance photometry
(enzymes, substrates, drugs of abuse)
Potentiometry
ISE (ion selective electrodes) Na
+
, K
+
, Cl
-
Temperature
Running conditions: 15-32°C
Transport and storage: -25 to +60°C
Humidity
Running conditions: 30-80% at 15-32°C, non
condensing.
Transport and storage: 10-95%, non condensing
Pollution
Degree 2 (IEC 61010-1)
Altitude
Max. 2000 m above sea level
Photometric
85 tests/h max.; 60 tests/h consolidated (with typical test
panel)
ISE
180 tests/h max.; 60-100 tests/h consolidated
(photometric and ISE mixed)
Sample handling
Manually by operator
Time to first result
5-10 min (photometric measurements)
2 min (ISE measurements)
Summary of Contents for Cedex Bio
Page 1: ...Cedex Bio System Operator s Manual Software Version 2 1...
Page 10: ......
Page 22: ...Roche Diagnostics A 14 Operator s Manual Version 3 1 1 Safety Cedex Bio System Safety labels...
Page 130: ...Roche Diagnostics A 122 Operator s Manual Version 3 1 4 Software Cedex Bio System Buttons...
Page 131: ...5 Daily operation B 3 6 Special operations B 91 7 Configuration B 133 Operation B...
Page 132: ......
Page 303: ...8 General maintenance C 3 Maintenance C...
Page 304: ......
Page 339: ...9 Messages and alarms D 3 10 Result flags D 23 11 Troubleshooting D 39 Troubleshooting D...
Page 340: ......
Page 392: ......
Page 471: ...Glossary F 3 Index F 11 Glossary and Index F...
Page 472: ......
Page 492: ...Roche Diagnostics F 22 Operator s Manual Version 3 1 Index Cedex Bio System...
Page 493: ...Revisions G...
Page 494: ......
Page 495: ...Roche Diagnostics Operator s Manual Version 3 1 G 3 Cedex Bio System 18 Revisions Revisions...
Page 496: ...Roche Diagnostics G 4 Operator s Manual Version 3 1 18 Revisions Cedex Bio System...