Normal operation
Installation, use and maintenance manual – Calorio M
23
6
6.1
WARNINGS
General warnings
Prior to using the appliance carefully read the
warnings in Chapter III.1
p. 4, providing impor-
tant information on regulations and on safety.
First startup by TAC
First start-up may exclusively be carried out by a
Robur TAC (Chapter 7
Never power the appliance off while it is run-
ning
NEVER power the appliance off while it is running
(except in the event of danger, Chapter III.1
p. 4),
since the appliance or system might be damaged.
Do not obstruct the fan intake or the outlet
grille.
Do not obstruct the air intake and flue gas ex-
haust ducts located outside the room.
6.2
CONTROL PANEL
6.2.1
Buttons function
▶
Button A
(on/off):
to turn on the gas-fired convector press this button
for 2 seconds (the display will show on, the room
temperature, the time, the day of the week and the
function symbols);
to turn off the gas-fired convector press the button
for 2 seconds (the display will show off; the time
and the day of the week and the red LED E will light
up).
▶
Button B
(Manual/Automatic/MENU): used to se-
lect manual operation (hand icon) or automatic op-
eration (clock icon). Press for more than 5 seconds to
access the user settings menu (Paragraph 6.5
p. 25).
▶
Button C
(Heating/Ventilation/RESET): used to se-
lect heating mode (radiator icon) or summer mode
(fan icon) and to reset the gas-fired convector in the
event of lock-out.
Pressing button A
for at least 2 seconds is in-
tended to prevent unwanted switching on and/or
off by unintentional pressing of the button.
Figure 6.1
Buttons function
A
On/off button
B
Manual/Automatic/MENU button
C
Heating/Ventilation/RESET button
D Knob
E
Red LED (light up when the gas-fired convector is off)
C
A
D
B
E
6.2.2
Meaning display icons
Table 6.1
Meaning display icons
Icon
Description
Meaning
off
The gas-fired convector is off
hand
The operation is manual
clock
The operation is automatic
lock
The keypad lock function is active
sun
Winter mode (maintaining comfort temperature)
moon
Winter mode (maintaining economy tempera-
ture)
alarm
Operating fault (Table 7.1
radiator
Winter operation
fan
Summer mode (ventilation on)
flame
Burner on (double flame = max. power, single
flame = reduced power)
The temperature shown on the display is the tem-
perature of the air entering the gas-fired convector
(as measured by the temperature probe located
near the lower grille). It is not room temperature.
6.2.3
Knob operation
The operations that can be carried out using the knob (D)
are summarised below:
▶
Rotate the knob clockwise or counterclockwise to se-
lect the menu items shown on the display or to change
the value of a numerical field.
▶
Press the knob to access the selected menu or to con-
firm an operation.