Robotiq Universal Controller
Instruction Manual
Robotiq inc. © 2008 - 2014
10
3.2 Environmental and operating conditions
The Controller is designed for industrial applications but requires clean conditions and is not water resistant. Always
respect the conditions specified for storage and operating environments :
SPECIFICATION
VALUE
Minimum storage/transit temperature
-22°F [-30°C]
Maximum storage/transit temperature
158°F [70°C]
Minimum operating temperature
32°F [0°C]
Maximum operating temperature
158°F [70°C]
Humidity (non-condensing)
20-80% RH
Vibration
< 0.5G
Others
Free from dust, soot or water
Free from corrosive gases, liquids or explosive
gases
Free from powerful electromagnetic interference
sources
Info
If environmental conditions present dust, dirt or water, additional protection of the Controller will
be required.