MANUAL DE INSTRUCCIONES
INSTRUCTION MANUAL
Avda. de Las Retamas 5. 45950 Casarrubios del Monte (Toledo) España
Tel: +34 91 616 50 20 Email: [email protected]
www.roblan.com
LED ICE FPL IP44
SENSOR
NOTES
The product should be installed by a qualified electrician. The manufacturer reserves the right to refuse warranty service if the
product shows signs of damage due to incorrect maintenance or installation. Surface mounted installation only.
Do not install the product in high temperature or humid place.
INSTALLATION
1. Turn off the power.
2. Turn the lamp difuser to losen and and separate from the housing. as shown in picture a.
3.Fix the housing with the expansion pipe and self-tapping screws as shown in picture b.
4.Connect the commercial power wire with the terminal block as shown in picture c.
5. Recheck if everything is well connected. Cover the housing with the lamp difuser and rotate to finish the installation (as
shown in picture d).Turn on the power.
a.
b.
c.
d.
WARNINGS:
*
Power should be cut off before installation, maintenance or inspection.
*
Please install and use the light strictly according to the instruction.
*
Do not disassemble or remold the product to avoid accident of electric shock or light failure.
*
The wall switch
only
controls the main power, not the emergency lighting.
*
If you discover any malfunction or abnormal condition, please informt the supplier.
ITEM NUMBER
ICEIP44SENFRW18F
ICEIP44SENFRW32F
Input Voltage(VAC)
220-240V AC
Input Current(A)
0.14
0.24
Power(W)
18
32
Power Factor
>0.9
Color Temperature(K)
3000WW/ 4000NW
Luminous Flux (Lm)
1500/1600
2800/3000
Beam Angle(°)
120
Lifespan (hour)
30000
Protection Rate
IP44
Working Temperature(°C)
-20-40
CRI (Ra)
>80
Detection sensitivity
10% / 25% / 50% / 75% / 100%
Hold time
5s / 30s / 90s / 3min / 20min / 30min
Daylight sensor
2lux / 10lux / 25lux / 50lux / Disable
Mounting height
6m Max.
Motion detection
0.5~3m/s
Detection angle
150°(wall installation)/ 360°(ceiling installation)
Measurements
105
360
115
410