ROBLAN CASAMBI 227CBUCOPD17MOLF Installation Manual Download Page 1

www.roblan.com

MANUAL DE INSTALACIÓN 

| INSTALLATION MANUAL

ROBLAN EUROPA S.A.

Avda. de las Retamas 5. 45950
Casarrubios del Monte
Toledo, Spain

ROBLAN COLOMBIA S.A.S.

NIT. 900.748.926-0

ROBLAN AUSTRAL SPA

ROBLAN UK LTD

This 

227CBUCOPD17MOLF

 Lighting 

Control has an IP66 rated 

weatherproof enclosure and can be 

surface mounted onto an external/

internal ceiling or wall. Confi gurable 

via the free to download Casambi 

APP on Google Play or Apple APP 

Store.

INSTALLATION

To be installed by a competent person with 
reference to BS 7671 or equivalent local standards. 
If in doubt consult a qualifi ed electrician.

•  Plan where the 

227CBUCOPD17MOLF

 is to be located 

(see diagrams 1 and 2). Switch off supply and 
check for hidden cables and pipes. 

•  The detector should be sited so that it is not 

shaded from daylight.

•  Make sure the power is isolated from the circuit.
•  Remove the front cover by by removing the two 

screws on the front face of the product.

•  The detector could be ceiling mounted up to 

17 metres high, via any of the four pre-drilled 
mounting holes only and must be mounted with 
the cable entering from below. 

•  Thread mains cable carefully through the entry 

point.

•  The 

227CBUCOPD17MOLF

 should be connected as 

shown in diagram 3:

  L - Live in.   N - Neutral in.

•  Replace the front cover ensuring the two screws 

are secured.

OPERATION

To check the operation of the 

227CBUCOPD17MOLF

:

•  Turn on the supply then after 20 seconds if the 

sensor has recognised movement of a person 
within its zone of detection. 

The control also features adjustable time out (time 
lag) control and daylight threshold control which 
are confi gured by the Casambi APP.

PRECAUTIONS

•  Do not place the 

227CBUCOPD17MOLF

 near heat 

sources, fans or in ventilated ceiling voids.

•  Do not place close to, or positioned such 

that, any light source points directly into the 

227CBUCOPD17MOLF

•  Ensure wires and cables are securely held within 

the connection terminals.

•  The 

227CBUCOPD17MOLF

 should be protected by

    a 5 or 6 Ampere mcb or fuse.
• 

Disconnect the 227CBUCOPD17MOLF from the 
circuit before performing insulation testing 
of the wiring circuit.

TECHNICAL DETAILS

INPUT

Voltage:

220 - 240Vac

Frequency:

50Hz

Max. mains current:

20mA

Standby current:

16mA

RADIO TRANSCEIVER

Operating frequencies: 2.4... 2,483 GHz
Max. output power:

+4 dBm

LUX PARAMETERS

Range:

5 - 2000 lux

OPERATING CONDITIONS 

Note: The temperature difference between the 

detection target and the background must be 

at least 4 °C.

Ambient temperature:

-20... +40 °C (lout 

0.05 A)

Storage temperature:

-25... +75 °C

Max. relative humidity:

0... 80%, non cond.

CONNECTORS

Terminal block 

Wire size:

0.5mm

2

 - 2.5mm

2

 

solid or stranded

Wire strip length:

6-7mm

Tightening torque:

0,4 Nm/4 Kgf.cm

MECHANICAL DATA

Dimensions:

75mm x 60mm x 

37mm

Weight:

100g (unpacked)

Degree of protection:

IP66

Protection class:

Built-in Class 2

Material (casing)

Flame-retardant 

polycarbonate/ 

Polypropylene.

Finish / Colour

Opaque /White (RAL 

9003)

Protection class:

Built-in Class 2

CONFORMITY AND STANDARDS

EMC emission:

EN60669-2-1:2004 

inc. A12:2010

EMC immunity:

EN60669-2-1:2004 

inc. A12:2010

Safety:

EN60669-2-1:2004 

inc. A12:2010

Environment:

Complies with WEEE 

and RoHS directives

5 YEAR WARRANTY

227CBUCOPD17MOLF

 comes with a 5 year warranty  

from the date of manufacture and is CE marked. 

N

L

230Vac

5A or 6A MCB 

or fuse

L - Live in.  N - Neutral in.

N

L

DIAGRAM 2

Suggested typical wiring

DIAGRAM 3 - DIMENSIONS IN MM

10

65

37

24

60

fron

s

t

ide

20mm threaded 

entry spout

inside

4 x mounting 

holes. 3M screws 

recommended 

(not supplied)

17

48

up to 20m
up to 24m

Strong detection zone 

i.e. person moving arm 

or walking towards PIR

For optimum coverage recommended 

mounting height: 17m

Secondary detection

zone i.e. person walking 

perpendicular to PIR

DIAGRAM 1 - CEILING MOUNTED DETECTION

DIAGRAM 2 - WALL MOUNTED DETECTION

Strong detection 

zone (up to 10m)

Recommended 

wall mounting 

height 1 to 2.2 

metres

 

 

 

227CBUCOPD17MOLF

IP66 Rated Compact Passive Infra Red (PIR) 
Occupancy/Person Detector & Photocell

Input: 220-240 Vac  50Hz                             

PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCT
NOTE: 

227CBUCOPD17MOLF

 is only compatible to work with CASAMBI enabled equipment

Reviews: