background image

1.  Installation Dimensions(Unit: mm)  

IP65

2. Installation and use- 

Screws, washers,nuts and anchor bolts 

not included. 

Fixture Arms for Floodlights

ARMBL50A1/ARMBL50A2: For 10W-50W floodlights

ARMBL80A1/ARMBL80A2: For 70W-200W floodlights

ARMBL50A1/ARMBL80A1

ARMBL50A2/ARMBL80A2

ARMBL50A1/ARMBL80A1

Floodlight Base

ARMBL50A2/ARMBL80A2

Floodlight Base

PLEASE READ CAREFULLY BEFORE INSTALLATION:

-Unpack and check the product carefully and gather all the necessary equipment and materials mentioned in point 2

-If the product looks damaged in any way, please keep the product in the packaging and contact the dealer.

-Do not attempt to use a damaged product

- The product should be installed by a qualified electrician. If installed incorrectly the warranty will be void. 

-Please turn off the power supply before installation or before manipulating the lamp in any way.

-Please check that the lamp voltage and input voltage are compatible before connecting.

-Non-professionals must not install or dismantle the lamps.

Surface Base Mounting:

 Drill Holes on the 

surface according to the Base drawing in point 1 

with a 6mm diameter drill. Place one Anchor Bolt 

in the hole of the wall and then fix the arm with 

screws, washers and nuts. 

NOTE:

For 10W Floodlight use M6 Anchor Bolt

For 20W-50W Floodlights use M8 Anchor Bolt

For 70W-200W Floodlights use M10 Anchor Bolt 

Items needed for 

Surface Base

 Mounting

Items needed for Floodlight Base mounting

Pass the cable through the open end on the surface base support

3. Installation methods

Wall Mounted

Roof mounted 

Upward light

Billboard 

Downward light

Surface Base