1. Installation Dimensions(Unit: mm)
IP65
2. Installation and use-
Screws, washers,nuts and anchor bolts
not included.
Fixture Arms for Floodlights
ARMBL50A1/ARMBL50A2: For 10W-50W floodlights
ARMBL80A1/ARMBL80A2: For 70W-200W floodlights
ARMBL50A1/ARMBL80A1
ARMBL50A2/ARMBL80A2
ARMBL50A1/ARMBL80A1
Floodlight Base
ARMBL50A2/ARMBL80A2
Floodlight Base
PLEASE READ CAREFULLY BEFORE INSTALLATION:
-Unpack and check the product carefully and gather all the necessary equipment and materials mentioned in point 2
-If the product looks damaged in any way, please keep the product in the packaging and contact the dealer.
-Do not attempt to use a damaged product
- The product should be installed by a qualified electrician. If installed incorrectly the warranty will be void.
-Please turn off the power supply before installation or before manipulating the lamp in any way.
-Please check that the lamp voltage and input voltage are compatible before connecting.
-Non-professionals must not install or dismantle the lamps.
Surface Base Mounting:
Drill Holes on the
surface according to the Base drawing in point 1
with a 6mm diameter drill. Place one Anchor Bolt
in the hole of the wall and then fix the arm with
screws, washers and nuts.
NOTE:
For 10W Floodlight use M6 Anchor Bolt
For 20W-50W Floodlights use M8 Anchor Bolt
For 70W-200W Floodlights use M10 Anchor Bolt
Items needed for
Surface Base
Mounting
Items needed for Floodlight Base mounting
Pass the cable through the open end on the surface base support
3. Installation methods
Wall Mounted
Roof mounted
Upward light
Billboard
Downward light
Surface Base