20 of 83
Step
8
.3 Reflector Installation
Install all threaded components
w
ith a minim
u
m
thread engagement of three threads. Apply s
u
fficient
amo
u
nt of high temperat
u
re, anti-seize pipe
compo
u
nd (P/N 91308001 or eq
u
i
v
alent) to threads
prior to engagement.
Step
8
.3.1 Reflector Installation with Hole
WARNING
Fire Hazard
Support reflector with reflector hanger
and support strap.
Reflector must not touch tube.
Failure to follow these instructions can result
in death, injury or property damage.
Description
Part Number
Sched
u
le 40 T
u
be/Reflector Hanger
02790300
Sched
u
le 40 Steel Pipe and Fittings
S
u
pplied by Others
Reflector
w
ith Hole,
96" (244 cm)
02750304