CRVSF-S
ERIES
I
NSTALLATION
, O
PERATION
AND
S
ERVICE
M
ANUAL
18 of 83
FIGURE 14: Critical Han
g
er Placement
Description
Part Number
Eyebolt T
u
rnb
u
ckle
91903202
Spring Hook 3/8"
91903301
T
u
be/Reflector Hanger
02790300
Cast-Iron Comb
u
stion Chamber
02721200-1P
Run Len
g
th
Typical Expansion
Minimum “X” Len
g
th
50' (15 m)
±1" (3 cm)
12" (30 cm)
100' (31 m)
±2" (5 cm)
24" (61 cm)
150' (46 m)
±3" (8 cm)
36" (91 cm)
200' (61 m)
±4" (10 cm)
46" (122 cm)
250' (76 m)
±5" (13 cm)
57" (145 cm)