28
Commissioning
The temperature of the feed in the mixer jar must correspond to the mixing temperature speci-
fied by the MP manufacturer.
►
Keep to the feed temperatures recommended in this operating manual.
5.12
Setting portion
So that the automatic feeder can dose and mix the components water and MP exactly, the dos-
ages must first be determined and set manually.
Note:
To set the portion sizes, please keep the following objects on hand: To set the
water
you
need a graduated cylinder with mL calibration. To set
MP
a gram-exact scale is needed.
5.12.1
Setting the water
1. Press
to exit automatic mode.
2. Press
. The LED next to the key lights up.
3. Hold an empty measuring vessel under the water outlet and press
. In the time that is
indicated in the control unit display, a certain amount of water is dispensed.
4. Measure the collected quantity.
5. Using
or
change the time as needed so that the desired amount is dispensed into
the measuring vessel.
6. Press
again and measure the dispensed amount.
7. Repeat the procedure until the desired amount has been precisely dispensed.
5.12.2
Setting the milk powder
1. Press
to exit automatic mode.
2. Press
. The LED next to the key lights up.
3. Hold an empty measuring vessel under the powder outlet and press
. In the time that is
indicated in the control unit display, a certain amount of MP is dispensed.
4. Measure the collected amount.
5. Using
or
change the time as needed so that the desired amount is dispensed into
the measuring vessel.
6. Press
again and weigh the dispensed amount.
7. Repeat the procedure until the desired amount has been precisely dispensed.