background image

0

  rESE.   

  SPEC.

 

 

LA.Ad. 

 

 

 

 

PAn 

(0-255)

 

 

 

 

tilt 

(0-255)

 

 

 

 

Zoom 

(0-255)

 

 

CodE

 

 

AdJ. 

 

 

 

 

 

Pan 

(0-255)

 

 

 

 

:

 

 

 

 

F.CAL 

 

 

 

 

 

 

Colo. 

(0-255)

 

 

 

 

 

 

:

 

 

 

 

 

 

dimr 

(0-255)

 

 

 

 

 

 

A.rES.

 

 

uPd.M.(No,YES)

 

 

 

 

 

 

 

 

Summary of Contents for Color Wash 575 AT Zoom AT series

Page 1: ... Version 1 4 ...

Page 2: ...n between fixtures 12 5 ColorWash 575 AT Zoom DMX Protocol version 1 0 13 6 Controller mode 16 6 1 DMX addressing 16 6 2 Remotely controllable functions 16 7 Stand alone mode 17 8 Control menu map 18 9 Control menu 21 9 1 Fixture Address 21 9 2 Slave control 21 9 3 Fixture informations 21 9 4 Personality 23 9 5 Lamp On Off 24 9 6 Manual mode 24 9 7 Test sequences 25 9 8 Stand alone setting 25 9 9 ...

Page 3: ...r caution Make sure that the available voltage is not higher than stated on the rear panel Always plug in the power plug least Make sure that the power switch is set to OFF position before you connect the device to the mains The power plug has to be accessable after installing the device Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord fr...

Page 4: ...ect holes only Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fas tened The lamp must never be ignited if the objective lens or any housing cover is open as discharge lamps may explose and emit a high ultraviolet radiation which may cause burns The maximum ambient temperature 40 C must never be exceeded Otherwise the lamp is switched off ...

Page 5: ...ns 2 Moving head 3 Yoke 4 Base Rear panel 5 Power switch 6 Power cord 7 Fuse holder 8 3 pin DMX output 9 3 pin DMX input 10 5 pin DMX output 11 5 pin DMX input Front panel 12 Mode button 13 Enter button 14 Up button 15 Down button 16 Display ...

Page 6: ...r wattage A lamp like this generates temperatures the device is not de signed for Damages caused by non observance are not subject to warranty Please follow the lamp manu facturer s notes Do not touch the glass bulb with bare hands during the installation Make sure that the lamp is installed tightly into the lampholder system Reclose the lamp cover and tighten the 3 screws Before striking the lamp...

Page 7: ...okwise to set the hot spot in the center of the image If you cannot detect the hot spot adjust the lamp until the light is evenly distributed 4 3 Inserting Exchanging colours DANGER Install the colours with the device switched off only Unplug from mains before If you wish to change colours open the top cover of the head by loosening 4 quarter turn fasteners on the top cover Gently bend out the col...

Page 8: ...k Live L Light blue White Neutral N Yellow Green Green Earth 4 5 Changing the power supply settings Both the transformer and the ballast must be connected correctly for the local AC voltage and frequency The wrong settings can cause poor performance or demage of the moving head The factory settings are printed next to the power switch If you want to change the power supply settings follow the inst...

Page 9: ...ule and fasten it by locking the four quarter turn screws 4 7 Installing top hats The ColorWash 575E AT Zoom can be fitted with various types of the top hats see chapter Technical specifi cations If you wish to install a top hat optional follow the instructions Switch the device off before installing the top hat Installing the top hat on the front lens holder of the fixture 1 Put desired top hat o...

Page 10: ...as where persons may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including but not limited to calculating working load limits installation material being used and periodic safety inspection of all installation material and the projector If you lack these qualifications do not attempt the installation yourself but instead use a professional structural rigger Improp...

Page 11: ...he omega holder 4 with M12 bolt and lock nut through the hole in the holder 2 Fasten the omega holders on the bottom of the base by inserting both quick lock fasteners 3 into the holes of the base and tighten fully clockwise 3 Fasten the safety rope 2 through the two apertures on the bottom of the base and over the trussing sys tem When installing fixtures side by side avoid illuminating one fixtu...

Page 12: ...n the DMX chain with the DMX input of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected Caution At the last fixture the DMX cable has to be terminated with a terminator Solder a 120 Ω resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture Building a master slave chain Connect the DMX ou...

Page 13: ...ng Disabled blackout while pan tilt moving Blackout while colour wheel moving Disabled blackout while colour wheel moving Reserved To activate following functions stop in DMX value for at least 3 s Lamp On reset total reset except pan tilt reset Pan Tilt reset Colour system reset Reserved Dimmer Strobe reset Zoom module reset Reserved Total reset Reserved Lamp Off Reserved step step step step step...

Page 14: ... 10 0 255 Colour wheel fine positioning Fine positioning proportional 9 8 11 10 0 255 Cyan Cyan 0 white 255 full cyan proportional 10 9 12 11 0 255 Magenta Magenta 0 white 255 full magenta proportional 11 10 13 12 0 255 Yellow Yellow 0 white 255 full yellow proportional 12 11 14 13 0 255 Conversion temperature filter 3200K 0 7200K 255 3200K proportional 13 12 15 14 0 255 Speed of CMY and conv temp...

Page 15: ...o slow Shutter open Random strobe effect from slow to fast Shutter open step step proportional step proportional proportional step proportional step 18 16 20 18 0 255 Dimmer intensity Dimmer intensity from 0 to 100 proportional 19 21 0 255 Fine dimmer intensity Dimmer intensity fine proportional Notes Short times are not used for long tracks e g 0 5s for track 0 255 DMX Times are restricted by the...

Page 16: ...ermination plug with 120 Ohm to the last fixture in the link in order to ensure proper transmission on the DMX data link 6 2 Remotely controllable functions Lamp The ColorWash 575 AT Zoom is to be operated with a Philips MSR 575 2 lamp A relay inside of the ColorWash 575 AT Zoom allows you to switch on and off the lamp via the control panel or via your DMX controller without affecting the rest of ...

Page 17: ...te these acts too e g if the master fixture has switched the lamp off no slaves can switch the lamp on The master fixture starts simultaneous program start in the other slave fixtures All fixtures have a definite syn chronized starting point when playing back their programs The number of running program is the same in all slaves and depends on the master s choice menu St AL Every fixture runs its ...

Page 18: ...Po ti totl rSEt La ti totl rSEt LA St totl rSEt tEMP Cur t boAr HEAd Hi tE boAr HEAd rSEt boAr HEAd DM In Pan 0 255 F dim 0 255 VErS IC1 b IC2 b IC3 b IC4 b IC1 L IC2 L IC1 r PErS r PAn On Off r tilt On Off dM Pr Mod 1 Mod 2 Mod 3 Mod 4 LA Pr LA Au On Off d L OF On Off dM On On Off dM OF On Off LA dE 0 1 90 s ...

Page 19: ... M On Off Col M On Off In Po Pan 0 255 F dim 0 255 Stor dF SE LAMP On Off MAn M PrE C Pan Pan 1 Pan3 dimr dim 0 dim C MAn C Pan 0 255 F dim 0 255 tESt Mod 1 Pan 0 255 tilt 0 255 Zoom 0 255 Go Mod 2 St AL Audi On Off Auto Off tESt PrG 1 PrG 2 PrG 3 PLAY tESt PrG 1 PrG 2 PrG 3 Edit PrG 1 PrG 2 PrG 3 St 01 St 99 Pan 0 255 S tim 0 1 25 5 s COPY ...

Page 20: ...20 rESE SPEC LA Ad PAn 0 255 tilt 0 255 Zoom 0 255 CodE AdJ Pan 0 255 F CAL Colo 0 255 dimr 0 255 A rES uPd M No YES ...

Page 21: ...llows you to control the slaves from the master s control panel in a master slave operation Select this function from the main menu and press ENTER Browse the list of all connected slaves SL C 1 SL C 9 by pressing UP or DOWN Select the desired slave and press ENTER button The matching slave control panel is available from the master control panel Note This function is available from the master fix...

Page 22: ...hows the max temperature of the head inside since the ColorWash 575 AT Zoom has been fabricated rSEt Maximum resetable temperatures boAr The function shows the maximum temperature on the main board since the counter was last reset In order to reset the counter to 0 you have to hold UP and DOWN and press the ENTER HEAd The function shows the maximum temperature of the head inside since the counter ...

Page 23: ... wait for a service intervertion If the lamp light sensor is switched off and at switching the lamp on the electronics will still try to ignite the lamp until it shines even when the lamp is damaged or absent on this account some electronics parts could be damaged DiSP Display adjusting This function allows you to change the display settings turn Select this function to turn the display by 180 d O...

Page 24: ...ial positions After switch ing the fixture on if DMX is not connected all effects will move to initial positions Use the UP and DOWN buttons to select desired channel and press ENTER Set the effect to the desired position using UP and DOWN buttons and confirm by pressing ENTER After having adjusted required effects select Stor to save all initial values to the memory dF SE Default Settings Select ...

Page 25: ... in a loop tESt The option starts built in test program PrG 1 The option starts created program No 1 PrG 2 The option starts created program No 2 PrG 2 The option starts created program No 3 Select the program you wish and press ENTER The selected program starts running By Pressing ENTER again is possible to pause the program running Edit Editing program Select this menu to edit or create the prog...

Page 26: ...When the positioning is finished select F CAL and press ENTER 1 Calibration via the control board Disconnect DMX controller from the fixture Press ENTER and use UP and DOWN in order to display the following items Colo Zoom dimr for very smooth function calibration Select one of them press ENTER and use the UP and DOWN in order to adjust their right value from 0 to 255 Then press ENTER to confirm o...

Page 27: ...Connect button If the conection is OK click Start Uploading button to start uploading It will take several minutes to perform software update If the option Incremental Update isn t checked all processors will be updated including processors with the same software version If you wish to update only later versions of processors enable the Incremental Update check box Avoid interrupting the process U...

Page 28: ...the lamp or igniter is old or as a result of the interference by neighbouring devices In these cases the message does not affect the fixture operating Sn Er This message appears if the lamp lighting sensor is failed PoEr This message will appear if the fixture was shortly disconnect from the main Zo Er zoom error This messsage will appear after the reset of the fixture if the magnetic indexing cir...

Page 29: ...on filter lowers the colour temperature from 7200K to 3200 K 30 colour macros Motors 13 high quality stepping motors controlled by microprocessors Electronics Addressing special functions setting effects calibration via control panel with 4 digit LED display Readout fixture and lamp usage receiving DMX values temperature etc Built in analyzer for easy fault finding error messages Remotely switchin...

Page 30: ... lighted object 2 0m Dimensions mm Dimensions of the fixtue Dimensions of the optional top hats Weight net EU version 30 5 kg US version 34 5 kg Accessories Omega holder 2 pieces No 99010420 Optional Accessories Flash cable RS232 DMX No 13050624 Module of Front wide angle lens D200 No 99011101 Top hat standard 45 No 10980044 Top hat long 70 No 10980045 Top hat 3 ring 45 No 10980046 Top hat 3 ring ...

Page 31: ...ing will not only ensure the maximum light output but will also allow the fixture to function reliably throughout its life A soft lint free cloth moistened with any good glass cleaning fluid is recommended under no circumstances should alcohol or solvents be used DANGER Disconnect from the mains before starting any maintenance work The front objective lens will require weekly cleaning as smoke flu...

Page 32: ... of the base with a fitting screwdriver from the housing anti clockwise 2 Remove the old fuse from the fuseholder 3 Install the new fuse in the fuseholder 4 Replace the fuseholder in the housing and fix it Specifications are subject to change without notice ...

Page 33: ...33 ...

Reviews: