Page 2: ...ture exterior view 4 4 Mounting 5 5 SubDrive 1 menu 8 5 1 Fixture Address A001 8 5 2 Fixture information InFo 8 5 3 Personality PErS 9 5 4 Manual mode Man C 9 5 5 Test sequences tESt 10 5 6 Stand alone setting St AL 10 5 7 Special functions SPEC 10 6 Technical specifications 14 ...

Page 3: ...xposed to extreme heat or dust Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened Operate the fixture only after having familiarized with its functions Do not permit operation by persons not qualified for operating the fixture Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons Please us...

Page 4: ...4 3 Fixture exterior view 1 Top cover 6 DMX Out 2 Fastening screws 7 Gore valve 3 Antenna cover 8 LED Output 4 Power In 5 DMX In ...

Page 5: ...m and two cable glands M12x1 5 serve for cable of diameter of 3 7mm We recommend to apply an adequate layer of the paste LOCTITE 5331 on the plastic holder of each cable gland before inserting it into the body of the gland Note enclosed reducing seal P N 13051388 serves for cable of diameter of 4 8mm Original seal has to be removed from the cable gland before installing the reducing seal This devi...

Page 6: ...Source Submersible II connection DATA 24V red wire Communication orange wire Ground blue wire 6 Connect the fixture to mains 7 Set desired parameters in the fixture menu DMX address operating mode etc by means of display and four control buttons 8 Screw the top cover of the fixture back Check that all screws are firmly tightened ...

Page 7: ...7 RB 3092 ...

Page 8: ...e number of operation hours of the SubDrive 1 and connected ArcSource Submersible II module P O t b the function shows the total number of operation hours of the SubDrive 1 since the SubDrive 1 has been fabricated P t b r the function shows the number of operation hours of the SubDrive 1 since the counter was last reset In order to reset this counter to 0 you have to press and hold the UP and DOWN...

Page 9: ... will go to full intensity during 5 seconds Max fade time is reduced from 8 sec to 5 sec Value OFF means that this function is disabled rGb C White counting If this function is On a white channel uses red green and blue channels in a proportion to the intensity of the white channel in order to maximize white output of theArcSource Submersible II If you wish to light only with white LEDs at white c...

Page 10: ...he step in the program E g If fade time 5 second and step time 20 second effects will go to the desired position during 5 seconds and after that they will stay in this position for 15 seconds before going to the next prog step 1 Use the UP DOWN buttons to find St AL menu and press the ENTER button 2 Use the UP DOWN buttons to select Edit menu and press the ENTER button 3 Use the UP DOWN buttons to...

Page 11: ...ture to the mains go to the MAn C menu and set the shutter dimmer red green blue and white channel at 255DMX and let the LED module heat up cca 1 hour 2 Go to the CAL t menu select 2700K item and by means of the rEd GrEn bLuE Vhit items adjust the 2700K colour temperature as exactly as possible u v 0 After calibration select and confirm item SAVE to save adjusted values 3 Go to the CAL t menu sele...

Page 12: ... continue in the software update you have to switch off and on the fixture to escape from the updating mode We recommend to cancel all running programs on your computer before starting the software update 5 Double click the software uploader file e g DSU_SubDrive_1 exe in the extracted files The Software Uploader program will start running 6 Select correct COM number if you use a Flash cable RS232...

Page 13: ...e fixtures especially large installation of fixtures is to use the ROBE Uploader It is a software for automatized software update of Robe fixtures It takes advantage of RDM support For more information please see https www robe cz robe uploader ...

Page 14: ...3 up to 40 steps each Settings Addressing Via RDM communicator or Robe Universal Interface RUNIT PHYSICAL Weight 3 kg 6 61 lbs Number of LED Output zones 1 Max Load Per Zone 1x ArcSource Submersible II Total Load 1x ArcSource Submersible II Max Cable Length 100m Minimum mode 50m Medium mode 25m Maximum mode LED Output Connection Terminal Block DMX Connection Terminal Block Power Connection Termina...

Page 15: ...mm inch September 10 2021 Copyright 2021 Robe Lighting All rights reserved All Specifications subject to change without notice Made in CZECH REPUBLIC by ROBE LIGHTING s r o Palackeho 416 20 CZ 75701 Valasske Mezirici ...

Page 16: ...ue Blue full Red Green White 0 step 17 55 Red 0 Green up Blue full White 0 proportional 56 Light Blue Red 0 Green full Blue full White 0 step 57 95 Red 0 Green full Blue down White Amber 0 proportional 96 Green Red 0 Green full Blue 0 White 0 step 97 134 Red up Green full Blue 0 White 0 proportional 135 Yellow Red full Green full Blue 0 White 0 step 136 174 Red full Green down Blue 0 White 0 propo...

Page 17: ...tep 192 223 Random strobe effect from slow fast proportional 224 255 Shutter open step Dimmer coarse all zones 0 255 Dimmer intensity from 0 to 100 0 default proportional Dimmer fine all zones 0 255 Dimmer intensity from min max 0 default proportional Halogen lamp effect during dimming Copyright 2021 Robe Lighting s r o All rights reserved All Specifications subject to change without notice 9 7 8 ...

Page 18: ...ones 0 31 Shutter closed step 32 63 Shutter open 32 default step 64 95 Strobe effect from slow fast proportional 96 127 Shutter open step 128 143 Opening pulses in sequences from slow fast proportional 144 159 Closing pulses in sequences from fast slow proportional 160 191 Shutter open step 192 223 Random strobe effect from slow fast proportional 224 255 Shutter open step Dimmer coarse all zones 0...

Page 19: ...es in sequences from fast slow proportional 160 191 Shutter open step 192 223 Random strobe effect from slow fast proportional 224 255 Shutter open step Dimmer coarse all zones 0 255 Dimmer intensity from 0 to 100 0 default proportional Dimmer fine all zones 0 255 Dimmer intensity from min max 0 default proportional Copyright 2021 Robe Lighting s r o All rights reserved All Specifications subject ...