Page: 12
TROUBLESHOOTING
Check all the following points before contacting a service agent.
If the Toaster does not start:
The power point is not faulty.
The machine is plugged in correctly and the power switched on.
The Lid is in the closed position. The amber and red pilots will flash alternatively
if the lid is opened.
The ON
– OFF switch is switched on. The green pilot light should be on.
If the conveyor stops during operation:
The machine may be in energy saving mode. Check the flash condition of the
amber pilot. Put bread in and see if it will start automatically.
If smoke is coming from the cooking cavity, turn off the machine and allow it to
cool. Open the top cover and check for anything stuck in the conveyor.
If the machine does not enter Energy Save mode:
Check the bread sensor works (see Sensor Test Mode). Note that if the bread
sensor does not work the machine will never go into energy saving mode.
If the machine trips the RCD:
Check Appendix A at the end of this manual on the subject of RCD’s.
Indicating Lights
Use this table to help diagnose the machine status.
Status
Amber Cook
Red
Chute Lights
Warm Up
QUICK FLASH
OFF
ON
Normal
ON
OFF
ON
Speed Locking
ON
QUICK FLASH
ON
Speed Locked
ON
ON
ON
Speed Unlocked
ON
OFF
ON
Motor Save
ON
OFF
ON
Energy Save
1 SECOND FLASH
OFF
ON
Sleep
2 SECOND FLASH
OFF
ON
Cover Open
1 SECOND FLASH ALTERNATELY
ON
Motor Failure
2 SECOND FLASH TOGETHER
ON
Over Temp.
4 SECOND FLASH TOGETHER
Sensor Test: Beam blocked
ON
DOUBLE FLASH
OFF
Sensor Test: Beam unblocked
OFF
DOUBLE FLASH
OFF
Summary of Contents for ST350A