Summary of Contents for 320-KD3005D

Page 1: ...USER MANUAL BEDIENUNGSANLEITUNG RND 320 KD3000 D P Series...

Page 2: ......

Page 3: ...mperature Constant voltage Constant Digital panel control 4 digits display Software calibration Over Current Protection Button lock function USB RS232 for remote control RND 320 KD3005P WARNING DANGER...

Page 4: ...re qualified as service personnel AC Input AC Inut Voltage 230 V 50Hz Connect the protective grounding conductor of the AC power cord to an earth ground to avoid electrical shock Operation Environment...

Page 5: ...protection replace the fuse only with the specified type and rating Disconnect the power cord before fuse replacement Make sure the cause of fuse blowout is fixed before fuse replacement MODEL 220 23...

Page 6: ...supply is in OCP mode this light is on C C indicates constant current When the power supply is in constant current mode this light is on C V indicates constant voltage When the power supply is in cons...

Page 7: ...or 2 seconds Mode 3 only for RND 320 KD3005P remote control mode programmable control mode Mode 1 Voltage Adjustment Knob Push the voltage adjustment knob and then the voltage meter will flicker when...

Page 8: ...to start OCP mode where the output will be cut off when the output current reaches the set value In the OCP mode rotate this knob to recover the output Press and hold for 3 seconds again and then the...

Page 9: ...e specifications below are tested under the conditions of temperation 25 C to 5 C and the warm up for 20 minutes RND 320 KD3005P D Model VOLTAGE RANGE CURRENT RANGE LOAD REGULATION VOLTAGE RANGE CURRE...

Page 10: ...5P USER MANUAL 1 POWER CORD 1 USB CABLE 1 USB RS232 WEIGHT AND DIMENSION 110MM W 156MM H 260 D 4 8 KG 10 mV 1 mA 150 ppm 150 ppm SETUP RESOLUTION VOLTAGE RANGE CURRENT RANGE SETUP ACCURACY 25 C 5 C VO...

Page 11: ...the COM port inside the PC according to the following list Baud rate 9600 Parity bit None Data bit 8 Stop bit 1 Data flow control None RS232 Interface Definition KD3005P DC POWER SUPPLY Functionality...

Page 12: ...output current Example ISET1 2 225 Sets the CH1 output current to 2 225A 2 ISET X Description Returns the output current setting Example ISET1 Returns the CH1 output current setting 3 VSET X NR2 Desc...

Page 13: ...oltage 7 OUT Boolean Description Turns on or off the output Boolean 0 OFF 1 ON Example OUT1 Turns on the output 8 STATUS Description Returns the POWER SUPPLY status Contents 8 bits in the following fo...

Page 14: ...umber 1 to 5 Example RCL1 recalls the panel setting stored in memory number1 11 SAV NR1 Description Stores the panel setting NR1 1 5 Memory number 1 to 5 Example SAV1 Stores the panel setting in memor...

Page 15: ...ation to another language are not allowed unless it is permitted And all rights are reserved The information in this manual is corre ct when printing However RND will continuously improve products and...

Page 16: ...16 Sicherheitssymbole Diese Sicherheitssymbole k nnen in diesem Handbuch oder in der Serie erscheinen WARNUNG GEFAHR Hochspannung Earth ground Terminal Deutsch...

Page 17: ...n bergeben Inhalt 1 Beschreibung und Funktion 3 2 Bestimmungsgem er Einsatz 3 3 Sicherheits Service und Betriebshinweise 3 4 Bedien Anschluss und Anzeigeelemente 4 5 Inbetriebnahme und Betrieb 5 5 1 A...

Page 18: ...ind als dies die maximalen Daten des Netzger tes zulassen Der Einsatz darf nur in trockener staubfreier Umgebung mit ausreichender Bel ftung erfolgen Einsatz nur in trockenen Innenr umen Der Einsatz d...

Page 19: ...sl segrund beseitigen Niemals andere Sicherungen als vorgeschrieben verwenden Ger t nur an einer Steckdose mit Schutzleiter betreiben Sorgen Sie immer f r ausreichende Bel ftung decken Sie niemals die...

Page 20: ...ohne Nutzung des Erdungsanschlusses 5 3 Ausgangswerte einstellen Stellen Sie anhand der Anzeige die gew nschten Werte f r Ausgangsspannung und Ausgangsstrom mit den Einstellern Voltage Current ein We...

Page 21: ...des H chststroms am Ger teausgang wird dieser nun sofort abgeschaltet Ein Wiedereinschalten des Ausgangs kann durch kurzes Drehen des Stromeinstellers erfolgen Mit erneutem Dr cken des Stromeinsteller...

Page 22: ...des Ger tes wiederum defekt konsultieren Sie unseren Reparaturservice 8 Technische Daten Netzspannung 110 230 V AC 50 60 Hz Ausgangsspannung 0 30 V DC Ausgangsstrom 0 5 A Lastausregelung Spannung 0 01...

Page 23: ...er Ihre kommunale Sammel stelle f r Elektronik Altger te The proprietary information in this manual is protected by copyrights Any photocopies reproductions or translation to another language are not...

Page 24: ...0 30 V DC Ausgangsstrom 0 5 A Lastausregelung Spannung 0 01 2 mV Strom 0 1 10 mA Netzausregelung Spannung 0 01 3 mV Strom 0 1 3 mA Aufl sung Einstellung 10 mV 1 mA Genauigkeit 25 C 5 C Spannung 0 5 20...

Page 25: ...setzungen in eine andere Sprache sind sofern nicht ausdr cklich bewilligt nicht erlaubt Alle Rechte vorbehalten Die Informationen sind zum Zeitpunkt des Druckes korrekt Da wir jedoch die RND Produkte...