11. CLOCK Section
The
CLOCK
section is used to inspect and configure the clock source and sample rate of the M-32 AD
Pro.
Web remote
Status Indicator
Selected Master (frame)
Word Clock Output Single Speed Setting
Current Master (white)
Current Master and Sample Rate
Master Selection Dropdown
Sample Rate Dropdown
Status Indicator
11.1. Clock status
The clock of all digital inputs is continuously monitored with
SyncCheck™
and shown in the
CLOCK
section. A
warning
occurs when the chosen clock master fails. A
caution
is displayed when a routed
signal is out of sync. A
caution notification
is displayed when a signal is present, but not in sync and not
routed. A
good notification
is displayed when a signal is present and in sync, but not routed or chosen
as clock master. A
confirmation
is shown when the signal is present and either chosen as master or
routed and in sync.
On the standby screen, the two possible
notifications
are not shown. Those signals are
not relevant to the current device state.
11.2. Master Clock
In its the default state, the M-32 AD Pro uses an internal clock signal (
master
). This means that any
connected device must synchronize to it (
slave
).
Alternatively, one of the digital inputs (word clock, MADI optical, MADI coaxial, and each of the four AVB
RME M-32 AD Pro User’s Guide
11. CLOCK Section |