56
User's Guide HDSP System HDSP 9652
© RME
24.14 Level Meter
The HDSP 9652 calculates all the display values Peak, Over and RMS in hardware, in order to
be capable of using them independent of the software in use, and to significantly reduce the
CPU load.
Tip:
This feature, the
Hardware Level Meter
, is used by
DIGICheck
(see chapter 16) to display
Peak/RMS level meters of all channels, nearly without any CPU load.
The level meters integrated in TotalMix - considering their size - cannot be compared with
DIGICheck. Nevertheless they already include many useful functions.
Peak and RMS is displayed for every channel. 'Level Meter Setup' (menu Options or F2) and
direct keyboard entry (
hotkeys
) make various options available:
•
Display range 40 or 60 dB (
hotkey 4 or 6
)
•
Release time of the Peak display (Fast/Medium/Slow)
•
Numerical display selectable either Peak or RMS (
Hotkey E or R
)
•
Number of consecutive samples for Overload display (1 to 15)
•
RMS display absolute or relative to 0 dBFS (
Hotkey 3 or 0
)
The latter is a point often overlooked, but
nonetheless important. A RMS measurement
shows 3 dB less for sine signals. While this is
mathematically correct, it is not very reasonable
for a level meter. Therefore the RMS readout is
usually corrected by 3 dB, so that a full scale
sine signal shows 0 dBFS on both Peak and
RMS meters.
This setting also yields directly readable signal-
to-noise values. Otherwise the value shown with
noise is 3 dB better than it actually is (because
the reference is not 0 dB, but -3 dB).
The value displayed in the text field is inde-
pendent of the setting 40/60 dB, it represents
the full 24 bit range of the RMS measurement.
An example: An
RME ADI-8 QS
connected to
the HDSP 9652's ADAT port will cause a level
readout of around -114 dBFS on all eight
channel's input level meters.
This level display of TotalMix also provides means for a constant monitoring of the signal qual-
ity. Thus it can be a valuable tool for sound optimization and error removal in the studio.
Measuring SNR (Signal to Noise) is best done with RME’s free software DIGICheck. The
function Bit Statistic includes three different RMS meters for exactly this purpose (RMS
unweighted, A-weighted and DC).
Summary of Contents for Hammerfall HDSP 9652
Page 5: ...User s Guide HDSP System HDSP 9652 RME 5 User s Guide HDSP 9652 General...
Page 38: ...38 User s Guide HDSP System HDSP 9652 RME...
Page 39: ...User s Guide HDSP System HDSP 9652 RME 39 User s Guide HDSP 9652 Connections and TotalMix...
Page 45: ...User s Guide HDSP System HDSP 9652 RME 45...
Page 66: ...66 User s Guide HDSP System HDSP 9652 RME...
Page 67: ...User s Guide HDSP System HDSP 9652 RME 67 User s Guide HDSP 9652 Technical Reference...
Page 75: ...User s Guide HDSP System HDSP 9652 RME 75 31 Block Diagram HDSP 9652...