![Rlide R2 PRO Manual Download Page 43](http://html1.mh-extra.com/html/rlide/r2-pro/r2-pro_manual_1467161043.webp)
41
o.
Screen returns to Input STN menu,
press [ENT] to record station and
backsight. Screen returns to Stn Setup
menu.
[ENT]
Input STN
ST:
10
1
HI:
1.800m
CD:
BS: 5
List
Stac
※
1)
About method to input PtID, please refer to “2.8
METHOD TO INPUT PTID
”.
※
2)dHA
:
Distributed HA errors in each direction
dVD
:
VD errors between measured distance and calculated distance
dHD
:
HD errors between measured distance and calculated distance
※
3)
To delete a measurement, highlight the measurement data, and then press the DEL softkey.
The STN
coordinates are automatically recalculated.
●The minimum data required for a resection is
either three angle shots, or two distance shot.
●Basically, Stn
-Z is calculated from distance-measured data. If no distances are measured, then Stn-Z is
calculated using angle-only measurements to known points with 3D coordinates.
4.3 QUICK STATION
Setting up the station quickly without coordinates
。
The station point (ST) in this function defaults to a new point number. For the new point, MP (0, 0, 0) is
stored as the coordinates. When the ST is manually changed to a known point name, the station is set up
on the coordinates of the known point.
Even if both ST and BS are known points, this function does not calculate the backsight angle (AZ)
automatically.
To calculate the AZ between two known points (ST and BS), use [Stn Setup]→[1.Known].
STEP
OPERATION
DISPLAY
c.
In [Stn Setup] press [3] to enter into Quick
Station function.
[3]
Stn Setup
1. Known
2. Rese
3. QuickStn
4. Z Coord
5. BS Check
d.
Input the point name of ST, and press
[ENT]. defaults to the last recorded PT +
1, or ST + 1, depending on the Split ST
setting)
※
1)
Input the point
name of ST
[ENT]
QuickStn
ST:
1
HI:
1.800m
BS:
AZ:
List
Stac