background image

PRODUCT MANUAL

PRODUCT MANUAL

Training and Technology for Injection Molding

Lynx™ Eight‑Channel Strain 

Gage Sensor Adapter with 

Mold ID

SG/LX8‑S‑ID

Summary of Contents for LYNX SG/LX8-S-ID

Page 1: ...PRODUCT MANUAL PRODUCT MANUAL Training and Technology for Injection Molding Lynx Eight Channel Strain Gage Sensor Adapter with Mold ID SG LX8 S ID...

Page 2: ...PRINT DATE 05 12 2022 REVISION NO 0...

Page 3: ...III ALERTS III PRODUCT DESCRIPTION APPLICATIONS 1 MULTI CHANNEL STRAIN GAGE MCSG SENSOR SYSTEM 1 OPERATION 1 STRAIN GAGE SENSORS 1 STRAIN GAGE SENSORS 1 DIMENSIONS 2 CABLE LENGTHS 2 INSTALLATION INST...

Page 4: ...NX CABLES AND CONNECTIONS FOR CONNECTION ISSUES 12 INTERFERENCE 13 INTERFERENCE WITH MACHINE INTERFACE MODULES AND SENSORS 13 INTERFERENCE FROM MOLD SENSORS 14 CUSTOMER SUPPORT 15 RELATED PRODUCTS COM...

Page 5: ...ses of the material or designs described herein are not to be construed as constituting a license under any RJG Inc patent covering such use or as recommendations for use of such material or designs i...

Page 6: ...Lynx Eight Channel Strain Gage Sensor Adapter with Mold ID SG LX8 S ID Product Manual iv NOTES...

Page 7: ...ystems provide quick convenient connection between multiple sensors in a mold to a single sensor adapter and the eDART or CoPilot system outside of the mold saving real estate and minimizing cabling O...

Page 8: ...tate safe installation and removal of connector from tool to prevent tension on the lead wire generally 2 3 50 75 mm of slack is sufficient Use good sense to determine the appropriate cable length req...

Page 9: ...eight channel strain gage sensor adapter to plate cable C SG LX8 S is installed on the SG Sensor Plate SG 8 Sensor Plate to Adapter Cable C SG LX8 S Sensor Adapter SG LX8 S ID LX8 S ID adapter and the...

Page 10: ...otential is equal to that used by the eDART or CoPilot system adapter and cables are free from contact with static sources such as feeder tubes and material hoppers 2 Mounting Mount the SG LX8 S ID to...

Page 11: ...or Scaling Setup window 3 will appear Fill in the window for each sensor to complete the SG LX8 S ID SG 8 and connected MCSG senors setup INSTALLATION SPECIFICATIONS continued Select the Sensor Model...

Page 12: ...ill appear when selected Click the to open the Mold Sensor Configuration window 4 The Mold Sensor Configuration window 4 will appear Fill in the window to complete the setup Select the ejector pin typ...

Page 13: ...amaged sensor heads A test report with sensor configuration can be emailed or printed from the device This device allows testing of up to thirty two sensors at one time and can verify that a force was...

Page 14: ...ne year from the original date of purchase The warranty is void if it is determined that the adapter was subjected to abuse or neglect beyond the normal wear and tear of field use or in the event the...

Page 15: ...ar proper PPE when needed to reduce the risks of any potential shocks or ungrounded equipment Please follow all safety guidelines TROUBLESHOOTING SOFTWARE FOR INTERMITTENT CONNECTIONS Use the Sensor L...

Page 16: ...will display as a count in the short stream count box and will indicate a dropout or miscommunication error NOTE Short Streams can show up when connecting or reconnecting sensors Short streams can als...

Page 17: ...hort streams and other information on the Raw Data Viewer Lynx Port Diagnostics window after swapping reconnecting or replacing cables The reset option is located at the bottom of the Lynx Port Diagno...

Page 18: ...the Raw Data Viewer Lynx Port Diagnostics window after swapping reconnecting or replacing cables The reset option is located at the bottom of the Lynx Port Diagnostics window To check Lynx cables and...

Page 19: ...terference and loose connections with the electrical buses in the machine conveyor belt or robot Verifying these connections and having the module wires away from any electrical interference will help...

Page 20: ...heat causing the electronics communications to fail and result in dropouts or damage When troubleshooting check the temperature of the mold or tool surface this also includes the transducer buttons R...

Page 21: ...Channel Strain Gage Sensor Adapter with Mold ID SG LX8 S ID 15 CUSTOMER SUPPORT Contact RJG s Customer Support team by phone or email RJG Inc Customer Support P 800 472 0566 Toll Free P 1 231 933 817...

Page 22: ...Lynx Eight Channel Strain Gage Sensor Adapter with Mold ID SG LX8 S ID Product Manual 16 NOTES...

Page 23: ...r 90 fittings One CE LX5 is required to interface the SG LX8 S ID with the eDART or CoPilot system LYNX EIGHT CHANNEL STRAIN GAGE SENSOR PLATE TO ADAPTER CABLE C SG LX8 S The Lynx Eight Channel Strain...

Page 24: ...that accommodates up to twenty four sensors All sensors are fully functional and properly named with a single cable connection from the mold to the eDART or CoPilot system PIEZOELECTRIC FOUR CHANNEL P...

Page 25: ......

Page 26: ...E A PTE LTD Singapore Republic of Singapore P 65 6846 1518 sales swg rjginc com en rjginc com FRANCE RJG FRANCE Arnithod France P 33 384 442 992 sales fr rjginc com fr rjginc com CHINA RJG CHINA Chen...

Reviews: