Lynx™ Strain Gage Button Sensors LS‑B‑127‑50/125/500/2000 | Product Manual
46
RJG, Inc.
SENSOR INSTALLATION CHECK—STATIC PIN INSTALLATIONS
Verify that the each sensor and static pin pocket is machined correctly.
1.
Protrusion Test (without sensor)
With only the static pin installed, push on the static pin; verify the pin protrudes clearance above
the pin head equal to 1/5th of the part thickness at pin location if part thickness is less than or equal
to 0.06” (1,5 mm), or 0.012” (0,3 mm) if the part thickness at pin location is greater than 0.06”
(1,5 mm).
2.
Flush Test (with sensor)
With the plates disassembled, sensor and pin in place, and cover plate removed, the end of the
static pin should be flush with the plate surface.
Static Pin
Static Pin
Sensor