![RJG Lynx LES-B-127-125 Product Manual Download Page 48](http://html.mh-extra.com/html/rjg/lynx-les-b-127-125/lynx-les-b-127-125_product-manual_1466485048.webp)
Lynx™ Embedded Sensors LES‑B‑127‑50/125/500/2000 | Product Manual
40
With the ejector and transfer pins installed, the ejector plate in the injection position, and
the ejector plate fixed towards clamp plate, press the ejector and transfer pin together,
away from the cavity; the ejector pin should recess in the ejector plate 0.008–0.01” (0,2–
0,3 mm).
3.
Flush Test (with sensor)
With the sensor, ejector, and transfer pin installed, and the ejector plate in the injection
position, fixed towards clamp plate, the ejector pin should be flush with the ejector plate/
cavity surface.
SENSOR INSTALLATION CHECK—CLAMP PLATE (HEAD‑TO‑HEAD) INSTALLATIONS
SENSOR INSTALLATION CHECK—CLAMP PLATE (TYPICAL) INSTALLATION (
continued
)
Ejector
Retainer
Plate
Ejector
Retainer
Plate
Clamp
Plate
Clamp
Plate
Ejector
Plate
Ejector
Plate
B Plate
or
Cavity
Insert
B Plate
or Cavity
Insert
Ejector Pin
Ejector Pin
Transfer Pin
Transfer Pin
Sensor