- 30 -
4.2.11
Contact pressure sensor
The pressure trigger ensures that the blind rivet can only be processed if the pressure
trigger is activated. This prevents accidental triggering and ensures that the parts to be
processed are lying next to each other.
The pressure trigger can be deactivated in the Freeset Manager Software as described below.
In order to deactivate the pressure trigger read out the tool by using the Freeset Manager
Software as described in chapter 4.3 on page 35.
•
Click
„programming“
•
Select the program, for example program 1, in which the pressure trigger should be
deactivated
•
Click
„option“
•
Remove the check mark next
to „Pressure
trigger“
(see image)
•
Click
„write“
DANGER
Risk of injury from unavailable / deactivated pressure trigger
Tools without, or with deactivated, pressure trigger can be triggered without
being placed on a part; significant risk of injury results from projectile rivets
•
The tools may only be used by trained personnel
•
Wear safety glasses and gloves
•
Guide the rivet into the mouthpiece only directly before beginning the
riveting process