2-26 Riverstone Networks RS 3000 Switch Router Getting Started Guide
Hardware Features
Introduction
Figure 2-16 Front panel of ATM Multi-rate line card
See
"Installing the ATM PHY Cards"
for instructions on installing PHYs into the ATM Multi-rate line
card.
The ATM Multi-rate line card has two available slots. Each slot accepts the following PHY interface modules:
The ATM Multi-rate line card uses the following LEDs.
Table 2-23 PHY modules for ATM Multi-rate line card
Port type
Specification
AIC-67
•
DS-3/T-3 interface (BNC Coax)
•
75 coaxial (RG-59B or equivalent) terminated with
75-ohm BNC connectors
•
Maximum of 450 ft (137 m) of cable
AIC-77
•
E-3 interface (BNC)
•
75 coaxial (RG-59B or equivalent) terminated with
75-ohm BNC connectors
•
Maximum of 450 ft (137 m) of cable
AIC-21
•
OC-3c MMF interface (SC-style)
•
EIA/TIA 492-AAAA
•
62.5/125 µm
•
Maximum of 2 kilometers of cable
•
0 to 9 dB loss at 1300 nm
AIC-29IR
•
OC-3c SMF-IR interface (SC-style)
•
EIA/TIA 492-CAAA
•
9/125 µm
•
Maximum of 15 kilometers of cable
•
0 to 15 dB loss at 1300 nm
Hot
Swap
Online
Offline