![Riverbed Steelhead 1050 Series Installation And Configuration Manual Download Page 33](http://html1.mh-extra.com/html/riverbed/steelhead-1050-series/steelhead-1050-series_installation-and-configuration-manual_1465716033.webp)
Steelhead Appliance Installation and Configuration Guide
33
Series xx00 and xx10 Status Lights and Ports
Overview of the Steelhead Appliance
Series xx00 and xx10 Status Lights and Ports
This section describes the status lights and ports for the Model xx00 and xx10.
Model 50, 100, 200, and 300
The following figure illustrates the Model 50, 100, 200, and 300.
Figure 1-8. Front Panel
LAN/WAN LEDs
Left LED
Link = Solid Green
Activity = Blinking Green
Right LED
GB = Orange
100 MB = Green
10 MB = No Light
Power Supply LEDs
Solid Green= Healthy power supply with AC power
connected.
Blinking Green= Unit is halted, but the power supplies
are still connected to AC power.
Solid Orange= AC power is not connected to this power
supply, but the unit is still powered on due to the other
power supply.
Solid Orange= Occurs when the power supply
automatically shuts off due to some error condition,
such as an overheat.
Blinking Orange= Indicates a power supply predictive-
fail condition, such as a fan failure. The power supply
may then shut itself off, which will change the LED to
solid orange. A log entry of this predictive-fail can be
viewed using the show hardware error-log all
command in the Riverbed Command-Line Interface.
No LED= No AC power connected.