Steelhead Appliance Installation and Configuration Guide
27
Environmental Specifications
Overview of the Steelhead Appliance
The following table summarizes power supply unit specifications for Model 3000, 3010, 3510, 5000, and
5010. The 5000 and 5010 power supplies are redundant and hot swappable. The 3000, 3010, and 3510 power
supplies are optionally redundant and hot swappable.
Environmental Specifications
The following table summarizes the environmental requirements for the Steelhead appliance.
5000
(3U)
2 x 460
W
8A-4 A
4.18 A
@110 V
N/A
1569
BTU
6 x 200
GB + 1
spare
512
GB
5.2 x 16.9 x
26 in
13.2 x 43.0 x
66.2 cm
67 lb.
30 kg
100-240 V
50-60 Hz
Double
460 W
(See
below)
5010
(3U)
2 x 460
W
8A-4 A
4.18 A
@110 V
N/A
1569
BTU
4 x 250
GB + 1
spare
512
GB
5.2 x 16.9 x
26 in
13.2 x 43.0 x
66.2 cm
67 lb.
30 kg
100-240 V
50-60 Hz
Double
460 W
(See
below)
Model 3000, 3010, 3510, 5000, and 5010
Output Power
460 W
Voltage
90 ~ 264 VAC Full Range
Frequency
47 ~ 63Hz
Input Current
8.0/4.0A for 115/230 VAC
Inrush Current
60A/80A Max. for 115/230 VAC per power module
Temperature (Operating)
0º - 35º C
Temperature (Storage)
-20º - 70º C
Hold Up Time
16 ms; minimum at full load and 90 VAC input voltage
Dimensions
84 x 101 x 300 mm
Cooling
2 38 x 38 x 38 mm DC fans
Power Inlet
Alternating Current (AC)
Model
Temperature
(Operating)
Temperature
(Storage)
Relative Humidity
Storage Humidity
Operating Altitude
50
0º - 50º C
32° - 122º F
-20º - 70º C
-4º - 158º F
20% - 80%
non-condensing
5% - 95%
non-condensing
Up to 10,000 ft.
100
0º - 50º C
32° - 122º F
-20º - 70º C
-4º - 158º F
20% - 80%
non-condensing
5% - 95%
non-condensing
Up to 10,000 ft.
200
0º - 50º C
32° - 122º F
-20º - 70º C
-4º - 158º F
20% - 80%
non-condensing
5% - 95%
non-condensing
Up to 10,000 ft.
250
0º - 45º C
32° - 113° F
-40º - 65º C
-40º - 149º F
20% - 80%
non-condensing
5% - 95%
non-condensing
Up to 10,000 ft.
Model
Power
(W)
Current
and Load
Typical
Power
Draw
BTU
Hard
Disk
Data
Store
Height,
Width,
and Depth
Weight
Voltage and
Frequency
PSU