Riva 52115211521 Installation Manual Download Page 26

26

 

 
 
 
 

 

 

 
 

www.rivatech.de 

APPENDIX (D): HEXADECIMAL-
DECIMAL CONVERSION TABLE 

Refer to the following table when you convert the MAC address of your device to IP address. 

 

 

 

Hex  Dec 

00  0 
01  1 
02  2 
03  3 
04  4 
05  5 
06  6 
07  7 
08  8 
09  9 
0A  10 
0B  11 
0C  12 
0D  13 

0E  14 
0F  15 

10  16 
11  17 
12  18 
13  19 
14  20 
15  21 
16  22 
17  23 
18  24 
19  25 
1A  26 
1B  27 
1C  28 
1D  29 

1E  30 
1F  31 

20  32 
21  33 
22  34 
23  35 
24  36 

 

Hex  Dec 

25  37 
26  38 
27  39 
28  40 
29  41 
2A  42 
2B  43 
2C  44 
2D  45 

2E  46 
2F  47 

30  48 
31  49 
32  50 
33  51 
34  52 
35  53 
36  54 
37  55 
38  56 
39  57 
3A  58 
3B  59 
3C  60 
3D  61 

3E  62 
3F  63 

40  64 
41  65 
42  66 
43  67 
44  68 
45  69 
46  70 
47  71 
48  72 
49  73 

 

Hex  Dec 

4A  74 
4B  75 
4C  76 
4D  77 

4E  78 
4F  79 

50  80 
51  81 
52  82 
53  83 
54  84 
55  85 
56  86 
57  87 
58  88 
59  89 
5A  90 
5B  91 
5C  92 
5D  93 

5E  94 
5F  95 

60  96 
61  97 
62  98 
63  99 
64  100 
65  101 
66  102 
67  103 
68  104 
69  105 
6A  106 
6B  107 
6C  108 
6D  109 

6E  110 

 

Hex  Dec 

6F  111 

70  112 
71  113 
72  114 
73  115 
74  116 
75  117 
76  118 
77  119 
78  120 
79  121 
7A  122 
7B  123 
7C  124 
7D  125 

7E  126 
7F  127 

80  128 
81  129 
82  130 
83  131 
84  132 
85  133 
86  134 
87  135 
88  136 
89  137 
8A  138 
8B  139 
8C  140 
8D  141 

8E  142 
8F  143 

90  144 
91  145 
92  146 
93  147 

 

Hex  Dec 

94  148 
95  149 
96  150 
97  151 
98  152 
99  153 
9A  154 
9B  155 
9C  156 
9D  157 

9E  158 
9F  159 

A0  160 
A1  161 
A2  162 
A3  163 
A4  164 
A5  165 
A6  166 
A7  167 
A8  168 
A9  169 
AA  170 
AB  171 
AC  172 
AD  173 

AE  174 
AF  175 

B0  176 
B1  177 
B2  178 
B3  179 
B4  180 
B5  181 
B6  182 
B7  183 
B8  184 

 

Hex  Dec 

DE  222 
DF  223 
E0  224 
E1  225 
E2  226 
E3  227 
E4  228 
E5  229 
E6  230 
E7  231 
E8  232 
E9  233 
EA  234 
EB  235 

EC  236 

ED  237 

EE  238 
EF  239 

F0  240 
F1  241 
F2  242 
F3  243 
F4  244 
F5  245 
F6  246 
F7  247 
F8  248 
F9  249 
FA  250 
FB  251 
FC  252 
FD  253 

FE  254 
FF  255 

 

 

 

 

 

 

 

Hex  Dec 

B9  185 
BA  186 
BB  187 
BC  188 
BD  189 

BE  190 
BF  191 

C0  192 
C1  193 
C2  194 
C3  195 
C4  196 
C5  197 
C6  198 
C7  199 
C8  200 
C9  201 
CA  202 
CB  203 
CC  204 
CD  205 

CE  206 
CF  207 

D0  208 
D1  209 
D2  210 
D3  211 
D4  212 
D5  213 
D6  214 
D7  215 
D8  216 
D9  217 
DA  218 
DB  219 
DC  220 
DD  221 

 

Summary of Contents for 52115211521

Page 1: ...1 www rivatech de RC3502HD 5211 Installation Guide ...

Page 2: ...TO QUALIFIED SEERIVCE PERSONEL This symbol is intended to alert the user to the presence of un insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons This symbol is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appli...

Page 3: ...ork environment 14 6 1 1 Generic IP Environment 14 6 1 2 Custom IP Environment 15 6 2 View video on web page 17 6 2 1 View video using IPAdmin Tool 19 6 3 Reset 20 6 4 Factory Default 20 APPENDIX A SPECIFICATIONS 21 Summary 21 Environment Condition 22 Mechanical Condition 22 APPENDIX B POWER OVER ETHERNET 23 PoE compatibility 23 Power classification 23 APPENDIX C DIMENSIONS 25 APPENDIX D HEXADECIM...

Page 4: ...64 MJPEG up to 30FPS 1080p Audio compression G 711 µLaw aLaw PCM Analog video output for installation only Video motion detection supported Two way mono audio supported Network RTSP HTTP protocol supported 10 100 Base T Ethernet Additional Features Micro SD card supported PoE supported Camera and Fan Built in Video Content Analysis SDK Software Development Kit provided IP66 certified Fan Heater un...

Page 5: ...amera DC power adaptor DC Jack Cable 9 pin and 2 pin terminal block Video out cable Screws and anchors Installation template Hex wrench driver Quick installation guide Silicon waterproof band Clamping core To prevent electromagnetic interference The above contents are subject to change without prior notice Note i ...

Page 6: ...ory Default Refer to 6 3 Reset and 6 4 Factory Default for more details Reset button is located under PCB 3 PAL NTSC button The initial factory version setting is free from PAL or NTSC Push the button once to set as PAL format Push the button twice to set as NTSC Push the button one more time to return to no video output mode Please note that the analog video signal is only Models herein and their...

Page 7: ...ncluded in the device package Connect this terminal block into this connector for cable connection of video output audio input output and digital input output Refer to 5 1 Connector for more details 5 LAN connector This is a RJ45 LAN connector for 10 100 Base T Ethernet 6 Micro SD card slot It is a memory card slot for external storage 7 Power Adaptor Connector DC 12V The camera needs a DC 12V 2 5...

Page 8: ...the waterproof silicon band on the bottom plate of the device 3 Drill three holes on the template and insert anchor blocks into the holes Fasten the camera with screws 4 Make sure the cables are properly connected by checking the LED button 5 Adjust the lens position by referring to 4 2 Setting the Lens Position 6 Put the dome cover on the main body of the camera Make sure the main body and the co...

Page 9: ...stable enough to support the camera If any reinforcement is needed consult with your safety personnel and proceed with the installation 4 1 Installation Template Installation template image s size scale in this installation guide is not 1 1 The correct size template design paper can be found inside the package separately Caution nstallation template 0 Caution ...

Page 10: ...lockwise Move it left or right and adjust the image focus After the setting tighten the focus puller again by turning it clockwise 4 3 Setting the Image Attribute You can set the image attribute of camera through the webpage The menu of image attribute can be seen under Setup Video Audio Camera Brightness contrast saturation and sharpness can be adjusted Zoom puller Focus puller C Tilt the lens A ...

Page 11: ...tion The camera provides 1 channel D I It can be connected to either a voltage type sensor or a relay type sensor as the following figures It can be selected by software Input voltage range 0VDC minimum to 5VDC maximum Max 50mA Input voltage threshold 1 5V Mic Amp Speaker ETHERNET MICRO SD DC12V DO DI 1 Out Out 1 VIDEO C C In AUDIO Reset 1 SW2 SW3 SW5 SW6 N A N A N A N A S W 1 ETHERNET MICRO SD DC...

Page 12: ... the relay type is supported Relay Rating Max 24VAC 50mA Do not exceed the maximum relay rating Must connect GND port which is located between systems Caution Caution Caution DO COM Relay Type Device Internal 5V DI COM DI COM Relay Type Voltage Type Output of Sensor Output of Sensor Internal Internal ...

Page 13: ...C button and go back automatically to none video output mode only installation process 5 LAN connection This is a RJ45 LAN connector for 10 100 Base T Ethernet Connect a LAN cable This LED lights up as orange and turns green when the encoder is powered on 6 12V DC Power A 12 DC power connector is required for this device 12V Red Black Video GND Red Black LED1 LED2 ...

Page 14: ...IP Environment In case of generic private network environment where IP address 192 168 XXX XXX are used users may view the live streaming images on a web page using the device s default IP address 1 Convert the device s MAC address to the IP address Refer to the Hexadecimal Decimal Conversion Chart at the end of the manual The MAC address of the device is attached on the side or bottom of the devi...

Page 15: ...oad from www rivatech de homepage IPAdminTool is a management tool which automatically scans all of the network products for users to perform administrative tasks which includes network configurations firmware update device reboot and device organizations To modify the device s default IP address for customized network area 1 Find the device from the IPAdminTool s list and highlight the device s n...

Page 16: ...ept the last 2 sets of IP Address which are to be the unique numbers for the device Refer to the image above for the setting 4 Click Setup to complete the modification When the dialog box appears to request user name and password enter the default value for the administrator account case sensitive as below ID root Password pass PC environment Info Give new unique IP address in last two sets and mi...

Page 17: ...live streaming images through a web browser The default username and password is root pass 1 The browser asks to install the ActiveX Click Allow 2 Setup exe installation link or pop up window appears depends on Microsoft Internet Explorer version Proceed with rest of setup installation ...

Page 18: ...e start the web browser again and check if video stream is displayed in the main view frame If This software requires the Microsoft XML Parser V6 or higher Please download MSXML6 from the Microsoft website to continue Error code Cannot create XMLDOMDocument message appears download and install the Microsoft Core XML Services MSXML 6 0 ...

Page 19: ... product list select the device by highlighting it 2 Right click the mouse and select Web view 3 The system s default web browser opens the device s address Please take care that the default system web browser is Microsoft Internet Explorer to support ActiveX plug in Whether directly accessing the streaming video through typing IP address on a web page or taking steps through IPAdminTool the Activ...

Page 20: ... is on press reset button and hold 2 Release the Reset button after about 5 seconds when green LED blinks at rate of 200ms 3 Wait for the system to reboot The factory default settings can be inferred as follows More Information To learn more about using other features of your devices refer to the manuals as Web Interface Manual or VCAsys_Online_Help which is available on USB stick or on www rivate...

Page 21: ...eams Dual Stream Configurable Resolution 1920x1080 1280x720 800x450 480x270 320x180 Compression FPS Up to 30fps 1080p Motion Detection Built in Burnt in Text Digital Video stream overlay text Output Analog video output for installation only Audio Input output 1 1 channel Compression Format G 711 Function Digital Input output 1 1 channel RS 485 Not supported Network 10 100 Base T Power over Etherne...

Page 22: ... On Video Output 1 Vp p 75Ω Composite for installation only Audio Input Linein 1 43Vp p Min 1 35Vp p max 1 49 Vp p 39 KΩ Audio Output Lineout 46mW Power 16 Ω D I Max 50mA 5VDC TTL level 1 5V threshold D O Max 50mA 24VDC On state resistance 50 Ω max continuous Environment Condition Operating Temperature Operating Range DC12V 40 C 50 C 40 F 122 F PoE 0 C 50 C 32 F 122 F Cold Start DC12V 20 C 4 F PoE...

Page 23: ...egulated low ripple and low noise output The AC DC converter also has built in overload and short circuit output protection Note For proper activation of 12V PoE the Category 5 cable must be shorter than 140m and conform the PoE standard PoE compatibility With non Power Sourcing Equipment PSE When it is connected with non PSE the power adaptor should be connected With power adaptor Connecting both...

Page 24: ... Minimum Power Levels Output at the PSE Maximum Power Levels at the Powered Device 0 Default 15 4W 0 44 to 12 95W Unlike the other way disconnecting PSE or PoE doesn t reboot the device as long as a power adaptor is connected Note i ...

Page 25: ...25 www rivatech de APPENDIX C DIMENSIONS Unit mm ...

Page 26: ...0 Hex Dec 6F 111 70 112 71 113 72 114 73 115 74 116 75 117 76 118 77 119 78 120 79 121 7A 122 7B 123 7C 124 7D 125 7E 126 7F 127 80 128 81 129 82 130 83 131 84 132 85 133 86 134 87 135 88 136 89 137 8A 138 8B 139 8C 140 8D 141 8E 142 8F 143 90 144 91 145 92 146 93 147 Hex Dec 94 148 95 149 96 150 97 151 98 152 99 153 9A 154 9B 155 9C 156 9D 157 9E 158 9F 159 A0 160 A1 161 A2 162 A3 163 A4 164 A5 1...

Page 27: ... 01 2012 Power consumption illumination variable update 01A 03 06 12 2012 Video PAL NTSC description corrected 01A 04 06 25 2012 DI DO specification corrected 01A 05 07 03 2012 Supporting protocol revised removed SOCK and SSH 01A 06 07 04 2012 Reset Factory reset description updated Ch 6 Configuration revised ...

Reviews: