Page 2: ...2 STATEMENT 3 ACCESSORIES 3 SAFETY INSTRUCTION 3 UNDERSTANDING DMX 6 TECHNICAL SPECIFICATION 8 CONTROL SYSTEM 10 CLEANING AND MAINTENANCE 17 ...

Page 3: ...carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do not discard the shipping carton in the trash Please recycl...

Page 4: ...tly into the light source of this fixture to prevent risk of injury to your retina which may induce blindness Those suffering from EPILEPSY should avoid looking directly into the light source of this unit at all times Always disconnect from main power source before performing any type of service and or cleaning procedure Only handle the power cord by the plug end never pull out the plug by tugging...

Page 5: ...n without knowledge how to do so DO NOT allow operation by persons who are not qualified to operate this type of fixture Most damages are the result of operations by nonprofessionals Consistent operational breaks may ensure the fixture will function properly for many years to come DO NOT shake fixture avoid brute force when installing and or operating fixture Always install the fixture with an app...

Page 6: ...0 times the weight of the fixture 210 lbs 95 kg Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing MOUNTING POINTS Overhead mounting requires extensive experience including amongst others calculating working load limits installation material being used and perio...

Page 7: ...s lights to lights get rid of the long relied twisted wires and achieve no delay real time in the data transferring DMX ADDRESSING All fixtures should be given a DMX starting address when using a DMX controller so the correct fixture responds to the correct control signal This digital starting address is the channel number from which the fixture starts to listen to the digital control information ...

Page 8: ...harging as soon as possible when get lights also more than 6 hours for first time DON T CHARGE THE LIGHTS WHILE USING IT WILL AFFECT THE BATTERY LIFE TECHNICAL SPECIFICATION Light Sources 6pcs 12W RGBWAP 6in1 LED Power Consumption 90W Power Voltage AC 100 220V 50 60Hz Display 1 8 inches FTF display Gross Weight 2 6Kgs Beam angle 25 WiFi control Communication distance Diameter 500M open area Workin...

Page 9: ...ual change gradual strobe sensitive 0 100 can be controlled by menu or remote 2 4G Wireless electronic switch turn it on or off on the menu check the icon on upper left corner of interface to know whether it is on or off White balance setting Adjust the brightness of the six colors also the role of fine tuning current The value is 127 255 The battery icon on upper right corner of interface can be ...

Page 10: ...ED 0 255 GREEN 0 255 BLUE 0 255 WHITE 0 255 AMBER 0 255 PURPLE 0 255 STROBE 0 20 Macro 1 32 Speed Show AUTO 0 20 FADE 0 20 SNAP 0 20 R STRO 0 20 G STRO 0 20 B STRO 0 20 A STRO 0 20 Sensitivity Sound SOUND1 0 100 SOUND2 0 100 SOUND3 0 100 Options User Settings Channel 006 010 Addressed DMX512 001 512 ...

Page 11: ...Icon YES NO 3 Display Sleep Open 5Sec 10Sec 15Sec 4 Autolock YES NO 5 FAN Control Auto High Medium Low 6 Infrared Setting ON OFF 7 Wireless Setting ON OFF 8 Factory Reset Password Information 1 LED Temperature 0 99 2 WORK Hours 001 999 3 SOFT Version 001 4 LEVEL Percent 10 100 1 1 Control interface 1 1 8 inches FTF display Display menu functions and parameters 2 Key definition ...

Page 12: ... the previous menu function status System parameters are automatically saved without pressing the Enter key Choose Pattern Choose Choose Pattern press ENTER display will display the corresponding menu function Like Such as static color macro function blending performance mode sound control mode Press UP DOWN to choose if press ENTER display will bring to next level menu funtion press Menu exit to ...

Page 13: ...Channel use UP DOWN to choose 6Ch or 10Ch press ENTER to DMX512 DMX512 address code use UP DOWN set the address code from 1 to 512 so The DMX512 console control signal can be received If you want to use this function please refer to the following to set the first four lamps DMX512 address 6CH 1 A001 2 A007 3 A013 4 A019 10CH 1 A001 2 A011 3 A021 4 A031 3 Slave build in program control When connect...

Page 14: ...rch the LedHome 1 2 Android system Open Google Play Store then search the LedHome Step 2 Setting the Wifi In User Settings interface press ENTER use UP DOWN to WiFi WIFI mode press ENTER button will show WiFi con indicates that the WiFi module is turned on at this point can be set through the mobile to connect control ...

Page 15: ...he first time you need to add a scene select Entertainment And then select the direct control there will be color ring control interface this time can be the appropriate mode of operation Different phone operating interface may be different but the function is the same 4 DMX512 channels 6 CHANNEL MODE NO Values Functions 1 0 255 Red dimming 2 0 255 Green dimming 3 0 255 Blue dimming 4 0 255 White ...

Page 16: ...0 ch choose the colors 30 49 Jump change number 10 ch control the speed 50 69 Gradual change number 10 ch control the speed 70 89 Mutation change number 10 ch control the speed 90 109 Ged strobe number 10 ch control the speed 110 129 Green strobe number 10 ch control the speed 130 149 Blue strobe number 10 ch control the speed 150 169 Amber strobe number 10 ch control the speed 170 189 UV strobe n...

Page 17: ... inside this fixture please refer all other service issues to our service technician Should you need any spare parts please order genuine parts from your dealer Please refer to the following points during routine inspections A detailed electric check by an approved electrical engineer every 3 months to make sure the circuit contacts are in good condition and prevent overheating Be sure all screws ...

Page 18: ... moving parts and make sure there are no signs of wear and rotate move without imbalances Electric power supply cables must not show any damage material fatigue or sediments Never remove the ground prong from the power cable ...

Page 19: ...19 Factroy No 31 Zhongxing Road Baiyun District Guangzhou China 86 20 2904 6476 info ricostagelight com www riukoe com Facebook YouTube ...