background image

GateGuard Model GGT-1/1F

DTMF Decoder

505 West Carmel Drive, Carmel, IN 46032  USA

P.O. Box 1998, Carmel, IN 46082-1998  USA

PH:  317-846-1201  •  FAX:  317-846-4978

Web:  www.ritron.com  •  Email:  [email protected]

GateGuard

™

Model GGT-1/1F DTMF DECODER

PROGRAMMING  &  CONNECTION  INSTRUCTIONS

Internal Relay Contact Specifications:

 Normally Open, 125 VAC @ 10amps

Warning! Do not exceed maximum rating.

I  M  P  O  R  T  A  N  T  !

1. If you purchased the RQX-454 Call Box (Basic or XT model) with the GGT-1 

GateGuard

 DTMF Decoder,

you must use the RITRON Model EXPO-12 External Power 12VDC Input/Battery Back-Up Kit.  The RQX-

454 does not have a connection available that would allow both the Decoder Board and the RQX radio

board to be turned off and draw no current when used only with batteries.  The RQX-150 and 450 do have

the necessary connection available, and can be used with batteries only or with the EXPO-12.

2. When using an XT Model Callbox with the RITRON Model EXPO-12, the installation of the liquid tight

strain relief in the EXPO-12 must be reversed due to space limitations in the XT case.

3. When using the GGT-1/1F with the 6-Series Callbox, the 6 D-cell battery holder must be removed and the

unit powered by an external 12 VDC power supply.

Step 1. - CALLBOX DISASSEMBLY 

-

 

Basic 

and

 XT

 Models RQX-150/156/450/456/454

1. For

 XT Model

  - Remove (4) metal screws with 

Torx T-25

 Tamper-proof screw bit. Remove front metal plate.

1. For 

Basic Model

  - Remove message placard from the front of the Callbox.

2. Loosen (4) large plastic screws located in the corners of the front enclosure.

3. Carefully pull front and rear enclosures apart.

4. Disconnect power cable between front and rear enclosures.

Note:

If the GGT-1F is installed in the XT Model OutPost, an additional hole must be drilled in the fiberglass enclosure

for  the routing of wires connecting the 

GateGuard

 decoder/relay board to the contact closure connection on the

device you wish to control.  The size and location of that hole will vary with each application and is therefore left up

to the installer/dealer. It is the installer/dealer responsibility to provide any conduit or strain relief hardware

needed.

Step 2. - INSTALLING THE GateGuard DECODER/RELAY BOARD INTO AN OUTPOST CALLBOX

Kit Parts List: (Special Note: If the GateGuard has been factory installed, proceed to Step 3)

-  RI-1 

GateGuard

 DTMF Decoder/Relay Board w/ foam tape.

-  Wire harness w/ connector.

-  Liquid Tight Strain Relief.

-  Instruction Sheet

Installation:

1. Solder the wire harness as shown in FIG.-1.

2. Remove the protective covering from the tape on the Decoder Board.

3.

RQX-150/450/454-XT:

 Place the Decoder Board on the inside left  wall of the front cover as shown in FIG.-2.

RQX-156/456-XT:

 The battery holder must be removed and the Decoder Board placed on the inside of the

back cover.

4. Connect the wire harness to the mating connector on the Decoder Board.  A panel mounted liquid tight strain

relief is included in the Kit. The liquid tight strain relief provides sealing as well as strain relief for the wires

connecting the 

GateGuard

 relay contacts to the contact closure inputs on the device you wish to control.

To install the liquid tight strain relief, you must drill a 

0.484" hole

 in the center of the bottom wall of the

enclosure that holds the radio (see FIG.-2. for details). 

IMPORTANT –

 Take care to study FIG.-2. For the

correct location of this hole 

BEFORE

 you drill the hole. Insert the liquid tight strain relief and tighten the

inside and outside nuts to secure it to the enclosure. 

IMPORTANT

 – After routing the wires through

the strain relief connector, firmly tighten the sealing nut. This will insure proper strain relief for the wires

and proper sealing of the enclosure.

5.

BEFORE

 you re-assemble the OutPost callbox – 

TEST 

your 

GateGuard

 system for proper operation.

Note:

If the GGT-1F is installed in the XT Model OutPost, a hole must be drilled into the fiberglass enclosure for the  routing of the

relay contact wires. The size and location of that hole will vary with each application and is therefore left up to  the installer/

dealer.  It is the installer/dealer responsibility to supply any conduit or strain relief hardware.

Pub. No.  

14500030