Rite-Hite
®
Owner's Manual
Genisys™ HL-900 Dock Leveler
Publication:
AMEN00160 2021‑08‑17
7
ELECTRICAL
Motor FLA/Connection Detail
HL‑900
MOTOR FLA RATINGS AND CONNECTION DETAIL
MINIMUM WIRE SIZE FOR LINE LENGTHS AND LINE LOADS
HALDEX
BUCHER
(PARTIAL MOTOR)
BUCHER
(FULL MOTOR)
LINE LENGTH
FLA
DETAIL
FLA
DETAIL
FLA
DETAIL
0‑50 FT
(0‑15 M)
51‑100 FT
(16‑30 M)
101‑150 FT
(31‑46 M)
151‑200 FT
(47‑61 M)
110-120/1/60/75HP
10
A
–
–
–
–
12 AWG
(4 mm
2
)
10 AWG
(6 mm
2
)
8 AWG
(10 mm
2
)
6 AWG
(16 mm
2
)
110-120/1/60/10HP
–
–
124
C
132
H
10 AWG
(6 mm
2
)
8 AWG
(10 mm
2
)
6 AWG
(16 mm
2
)
6 AWG
(16 mm
2
)
208-240/1/50/75HP
50
B
–
–
–
–
14 AWG
(25 mm
2
)
14 AWG
(25 mm
2
)
14 AWG
(25 mm
2
)
12 AWG
(4 mm
2
)
208-240/1/50/10HP
–
–
70
D
82
J
14 AWG
(25 mm
2
)
12 AWG
(4 mm
2
)
12 AWG
(4 mm
2
)
10 AWG
(6 mm
2
)
208-240/1/60/75HP
50
B
–
–
–
–
14 AWG
(25 mm
2
)
14 AWG
(25 mm
2
)
14 AWG
(25 mm
2
)
12 AWG
(4 mm
2
)
208-240/1/60/10HP
–
–
66
D
71
J
14 AWG
(25 mm
2
)
12 AWG
(4 mm
2
)
12 AWG
(4 mm
2
)
10 AWG
(6 mm
2
)
208-240/3/60/10HP
38
E
30
E
27
E
14 AWG
(25 mm
2
)
14 AWG
(25 mm
2
)
12 AWG
(4 mm
2
)
12 AWG
(4 mm
2
)
380-415/3/50/10HP
25
F
17
F
15
F
14 AWG
(25 mm
2
)
14 AWG
(25 mm
2
)
14 AWG
(25 mm
2
)
14 AWG
(25 mm
2
)
440-480/3/50/10HP
19
F
15
F
13
F
14 AWG
(25 mm
2
)
14 AWG
(25 mm
2
)
14 AWG
(25 mm
2
)
14 AWG
(25 mm
2
)
575-480/3/60/10HP
15
G
14
G
12
G
14 AWG
(25 mm
2
)
14 AWG
(25 mm
2
)
14 AWG
(25 mm
2
)
14 AWG
(25 mm
2
)
NOTE:
For line lengths over 200 ft (61 m), contact your local Rite-Hite representative
1 PH CONNECTION DETAIL
3 PH CONNECTION DETAIL
If rotation is wrong, reverse T5/5 and T8/8
Motor rotation is not reversible
Switching red and black will reverse rotation
If rotation is wrong, reverse any 2 lines
Haldex
Bucher
(Partial Motor Base)
Bucher
(Full Motor Base)
Figure 2