Trouble Shooting 

Problem Solution 

Water in Trough Too 

Warm  

Adjust thermostat to lower temperature 

Check to see if thermostat has failed by contacts burning closed 

Ice in Trough 

Check fuses or circuit breakers 

Check all heating elements to make sure they are working and hot 

Adjust thermostat to higher temperature 

Check for voltage from thermostat output 

Check voltage to fountain with and without electrical load 

Check that heaters are wired properly 

Valve Freezing 

Check that cable heater is installed properly and fastened to water supply line and is 

working when heaters are hot 

Check for missing or damaged insulation 

Check for air gaps for wind penetrations 

Supply line Freezing 

  

 

Check that the cable heater is uncoiled and fastened around valve, to supply line 

and is working when heaters are hot 

Check that supply piping is centered in riser tube 

Check that riser tube is free of water and mud that may freeze 

Check that flexible hose does not touch side of casing or frame 

Check casing for air leaks 

Check for air gaps between casing and concrete floor 

Valve won’t stop dripping 

Check float adjustment. Check for waterlogged float, or float rubbing on side of 

valve compartment 

Disassemble valve 

and check for sand or 

scale in valve rubber. 

Also check valve 

orifice outlet for wear 

and damage. A screen 

or filter my be required 

with sandy or scaly 

water 

 

Turn valve rubber over 

and re-assemble 

Check for excessive water system pressure 

Low water flow 

Check that valve inlet is not plugged or supply hose is not kinked 

Check system pressure from supply hose by installing a tee and a pressure gauge 

directly in front of the valve to check pressure drop when valve is open. A severe 

pressure drop indicates a restriction or undersized supply system. 

Check that shutoff valves are fully open 

 

Pin must be pushed out of valve

to dissemble

1/2”

Valve

3/4”

Valve

Valve Rubber

Valve Rubber

Cattle, Combination, and AC Series 

Fountains Installation Instructions

7

17 October, 2012

Summary of Contents for 1AC

Page 1: ...Congratulations you have just purchased the finest watering fountain on the market This unit is built to give you excellent service when properly installed and maintained Please follow instructions c...

Page 2: ...fore connection to fountain Water supplies with foreign material such as sand rust etc may require a filter to keep fountain valve working properly C Electric Supply It is usually most cost effective...

Page 3: ...concrete to keep air from leaking under fountain H Final Water Connection Connect the top of the supplied hose to the valve cut hose to proper length and slip onto the barb fitting of the valve assemb...

Page 4: ...t be made and maintained in strict conformity with National Local plumbing codes and National Local electrical codes CSA in Canada The applicable provisions of these codes take precedent Failure to ma...

Page 5: ...d If you are using solid wire then you will be able to just push the wire into the slot Stranded wire will require you to press the button down HEATER 240V FENWAL THERMOSTAT CABLE HEATER TERMINAL BLOC...

Page 6: ...nd fix any leaks Adjust float for a water depth of 2 inches below top of trough or overflow pipe by adjusting the thumbscrew or wing nut P Install Side Access Panel and Cover Once all water line conne...

Page 7: ...rmal service or handling and to any products altered or repaired with other than original equipment or manufacturer s parts This warranty gives you specific legal rights and you may also have other ri...

Page 8: ...of water and mud that may freeze Check that flexible hose does not touch side of casing or frame Check casing for air leaks Check for air gaps between casing and concrete floor Valve won t stop drippi...

Page 9: ...kg Optional 1 PKG 18320 O Ring Fenwal 6 pkg 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18074 Nut Brass Fenwal 6 pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 8 15154 Screw 1 4 x5 8 TC SS 10 pkg 1...

Page 10: ...kg Optional 1 pkg 18320 O Ring Fenwal 6 pkg 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18074 Nut Brass Fenwal 6 pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 8 15154 Screw 1 4 x5 8 TC SS 10 pkg 1...

Page 11: ...11515 Valve Bracket 1 2 w screws 1 pkg 9 18114 Trough Bolt Nut 5 pkg 1 pkg 28 12575 Red Valve 1 2 1 pkg 10 18628 Drain Plug 2 pkg 1 pkg 29 13613 Float with Short Arm 1 pkg 11 11419 Heater 120V 250W 1...

Page 12: ...Optional 1 pkg 7 11885 Disc Thermostat pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 8 15158 J Bolt Nut ZP 10 pkg 1 pkg NS 18323 2AC Accessory pkg 1 pkg 9 17500 Drain Pipe Guard 1 NS 15652 2AC Ca...

Page 13: ...2 pkg Optional 1 pkg 7 11885 Disc Thermostat pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 8 15158 J Bolt Nut ZP 10 pkg 1 pkg NS 18323 2AC Accessory pkg 1 pkg 9 17500 Drain Pipe Guard 1 NS 18059 2...

Page 14: ...Htr 120V 48W 1 pkg 1 pkg 7 11885 Disc Thermostat pkg 1 pkg NS 18323 1AC Accessory pkg 1 pkg 8 15158 J Bolt Nut ZP 10 pkg 1 pkg NS 15651 1AC Casing Insulation pkg 1 plg 10 18628 Drain Plug 2 pkg 1 pkg...

Page 15: ...Fountain Model Part Hole to Hole Location 3 Cattle Fountain 16743 15 1 2 x 30 5 Cattle Fountain 16745 18 1 8 x 38 1 2 3 Combination Fountain 16769 15 1 2 x 30 1 AC 18034 8 1 2 x 18 2 AC 18033 8 7 16...

Reviews: