background image

RISH

Insu

20

M

W

50V

100V

250V

500V

1KV

V

7

TEST

ON

OFF

ESC

STORE

V M

W

W

fused

600V CAT II / 300V CAT III

6

5

4

3

2

1

600V

3

(1) Liquid Crystal Display

(11) Symbols for displaying the 

(2) ON/OFF push button

selected functions

(3) Push button

(12) Display for selected function

(4) Push button

(13) Display for the unit of

(5) TEST Push button

measured quantity

(6) Function selector switch

(14) Over range Indication

(7) Terminal sockets

(15) Pointer for Analog indication

(8) External Power supply jack (Optional)
(9) Symbol for

(16) Scale for Analog Indication

“CONTINUOUSLY ON”

(17) Activated stop watch Indicator

(10) Digital display with indication

(18) Zero adjust indicator

of decimal point and polarity

(19) Low battery indicator
(20) Buzzer indication

Contents

Page

1

Safety Features and Precautions

4

2

Initial Start-Up

5

3

Selecting Measuring Functions

6

4

Liquid Crystal Display

6

4.1

Digital Display

6

4.2

Analog Display

6

4.3

Backlit

6

5

Insulation Resistance Measurement (M

W

)

7

5.1

Preparation for measurement

7

5.2

Insulation resistance measurement

7

5.2.1

Manual Insulation resistance measurement

7

5.2.2

Continuous measurement for a pre-selectable time

8

5.3

Conclusion of measurement and discharging

8

6

Additional Features

8

6.1

Pre-selectable limit checks (Go / No-Go option)

9

6.2

Storing the measured resistance value

9

6.3

Minimum value and Maximum value “MIN/MAX”

9

storage facility

7

Continuity Testing and Resistance Measurement

11

7.1

Continuity Testing

11

7.2

Low Ohm Measurement

11

7.3

Zero adjustment

11

8

Voltage Measurement (VAC/DC)

12

9

Default Live Circuit Warning

12

10

Stop Watch

13

11

Menu Structure

13

11.1

Description of Menu items

14

11.1.1

Setting the GoNoGo values

14

11.1.2

Setting the Timer values

14

11.1.3

To see the stored values

14

12

Specifications

15

13

Maintenance

18

13.1

Battery

18

13.2

Operation with mains Adapter (Optional)

18

13.3

Fuses

19

13.4

Housing

19

MIN MAX 400

100kM

600

10kM

VAC VDC

ON

200
1MG

800
1kM

F

A

G

M

k

100k

1000

10MG

8

L

L

ZERO

8

(optional)

MIN MAX 400

100kM

600

10kM

VAC VDC

ON

200
1MG

800

1kM

F

A

G

M

k

100k

1000

10MG

8

L

L

ZERO

20

17

9 19 10

11

12

13

18 14

15

16

CE

Summary of Contents for Insu20

Page 1: ...7 5 1 Preparation for measurement 7 5 2 Insulation resistance measurement 7 5 2 1 Manual Insulation resistance measurement 7 5 2 2 Continuous measurement for a pre selectable time 8 5 3 Conclusion of...

Page 2: ...NTINUOUSLYON mode Switching the Instrument Off Press ON OFF pushbutton for a longer time 5 ON 1 Safety Features and Precautions You have selected an instrument which provides you with a high level of...

Page 3: ...test after measurement may be life endangering in such cases 5 2 Insulation resistance measurement The instrument provides flexibility for both manual and continuous for a pre selectable time insulat...

Page 4: ...ion resistance measurement as well as for Ohms Continuity ranges Refer to the 11 Menu structure section for how to set the value for the noGo value 6 2 Storing the measured resistance value l To store...

Page 5: ...gnal if the measured resistance value is less than the pre setted GoNoGO value Default value is 0W Refer to the 11 Menu structure section for how to set the value for the limit value 7 3 Zero adjustme...

Page 6: ...ent only the Insulation Tests are available Note The default live circuit warning does not operate i when in STOPWATCH mode ii when in MENU structure 2 9 2 M W 50V 100V 250V 500V 1KV V 10 StopWatch Th...

Page 7: ...ee the first stored value The scale pointer is used to indicate the number out of 10 of the displayed stored value 2 Now you can view the successive stored value using the key The scale pointer also i...

Page 8: ...al Input 100 240 VAC 50 60 Hz Output 12 VDC 1000 mA Polarity Auto turn OFF Instrument turns off automatically if any of the keys or the function selector switch have not been activated for about 10 mi...

Page 9: ...ical Design Protection Instrument IP50 For terminal socket IP20 according to DIN VDE 0470 Part 1 EN60529 Dimensions W x H x D 84mm x 195 mm x 35 mm Weight 500 g including battery 13 Maintenance Attent...

Reviews: