background image

RTTE Compliance Statement

Hereby, RISCO Group declares that this equipment is in 
compliance with the essential requirements and other 
relevant provisions of Directive 1999/5/EC. For the CE 
Declaration of Conformity please refer to our website: 

www.riscogroup.com

MAIN FEATURES

The RWX73M is a 2-way supervised transmitter that 
combines the Magnetic/Door Contact (against opening doors
and windows) with an additional universal input or shutter. 

The RWX73M operates with RISCO’s 2-way wireless 
systems.

NORMALLY  CLOSED

INPUT CONFIGURATION

NORMALLY  OPEN INPUT

CONFIGURATION

Step 2: Input Wiring

Use the following diagrams for appropriate input 
termination wiring. For DEOL termination connect 
two 10 K Ohm resistors (supplied) illustrated as follows:

ALARM

DETECTOR

ALARM

DETECTOR

INSTALLATION

Ɣ

 Communication: Bi-directional

Ɣ

 Range: up to 300 m (1,000 ft.) range line of sight

Ɣ

 Supervision: Up to 255 minutes

Ɣ

 Selective input termination : NO, NC, DEOL, shutter

Ɣ

 Selective input  response: 10 / 500 ms 

Ɣ

 Tamper protection: back + cover

 

Step 1: Transmitter-to-Receiver Communication Setup

The RWX73M must identify itself to the system's receiver

by writing its coded message into the receiver's address 
memory. 

This registration is performed either by entering the 
RWX73M’s 11-digit serial code number or by performing 
the following RF allocation steps:

1. Remove the front cover (Fig 1)
2. Set the main unit to Learn mode.
3. Remove the battery from the insulation material and 
    reinsert it into the transmitter, paying attention to the 
    polarity (Fig. 2).
4. Send a write message by pressing the front tamper 
    switch (without detaching the back bracket) for at least   
    3 seconds until panel recognition is displayed (Fig. 2).            
NOTE: Wait at least 1 minute before closing the front cover.

DOUBLE END OF LINE INPUT CONFIGURATION

10k

ALARM

TAMPER

10k

DETECTOR

Step 3: Selecting the Mounting Location

1. Select a location best suited for communication quality 
    and near the intended wired detector. It is recommended
    to place the unit at the highest possible position.
2. Temporarily attach the unit to this point using two-sided 
    adhesive tape.
3. Generate an alarm signal (by momentarily opening or 
    closing the input terminals) and verify that the receiver 
    has received the signal. If the alarm signal is not
    detected, reposition the transmitter and try again.

Step 4: Mounting (Fig. 3 -- Fig. 6)

1. Detach the back of the transmitter from the back bracket
    (Fig. 3A). At mounting location note the alignment marks 
    for both components (Fig. 3B), and then install accordingly   
 

2. Detach magnet casing (Fig. 4A)  and install with mounting 

Notes:

3. The mark on the magnet's case must be aligned with 
    the mark on the transmitter's case (Fig. 5). 
4. For installations on wood or alloy, the maximum distance   
    for normal operation is 10 mm (1 cm), while for metal  
    ferromagnetic materials (such as iron) it is 5 mm (Fig. 5).

TAMPER SW1

LED

BATTERY

ANTENNA

+

-

C  RISCO

IN2

T.B

Step 5: De

¿

ning Parameters 

The following parameters can be de

¿

ned for RWX73M:

  

Parameter          Option 

  Supervision         Yes/No 
  LED Enable         Yes/No 
  Magnet 

           Enable/Disable      

  Alarm Hold          On/Off 

                   

  Termination         IN2:   NO/NC/DEOL/Shutter 

 

 

TECHNICAL SPECIFICATIONS

ELECTRICAL

Battery Type: 

      CR123 3V Lithium Battery

Current Consumption:        11

—

A standby

Frequency:                          RWX73M86800B 868.65 MHz
                                            RWX73M43300B 433.92 MHz
Dead Time (HOLD ON):     2.5 minutes
Supervision Transmission: 0-255 minutes
Modulation Type:  

      ASK

Battery Life:      

      3 years typical

Contact Size:   32 x 35 x 72 mm (1.3 x 1.4 x 2.8 in.)
Magnet Size:   16 x 11 x 72 mm (0.6 x 0.44 x 2.8 in.)

ENVIRONMENTAL

RF immunity: 

      According to EN 50130-4

Operating temperature:      -10° C to 55° C (14° F to 131° F)
Storage temperature:         -20° C to 60° C (-4° F to 140° F)

Speci

¿

cations are subject to change without prior notice.

Should any questions arise please contact your supplier.

LED INDICATION

Ɣ

 Upon successful learning: short 

À

ash sequence

Ɣ

 Normal operation: brief light upon transmission

Ɣ

 Low battery: short 

À

ash sequence during transmission

EN 50131-2-6 Grade 2 Environmental Class II

2-Way Wireless

Magnetic Door/Window Contact 

with Shutter

(Model RWX73M)

© RISCO Group  10/2014 

                        5IN2255 B

  Response            10 ms / 500 ms 

The RWX73M reports events from IN2 and from the magnetic   

the input or magnet are triggered. When restored, it transmits 

RISCO Group Limited Warranty 

RISCO Group and its subsidiaries and af

¿

liates ("Seller") warrants its 

products to be free from defects in materials and workmanship under 
normal use for 24 months from the date of production. Because Seller 
does not install or connect the product and because the product may 
be used in conjunction with products not manufactured by the Seller, 
Seller cannot guarantee the performance of the security system 
which uses this product. Seller's obligation and liability under this 
warranty is expressly limited to repairing and replacing, at Seller's 
option, within a reasonable time after the date of delivery, any product 
not meeting the speci

¿

cations. Seller makes no other warranty, 

expressed or implied, and makes no warranty of merchantability or of 

¿

tness for any particular purpose. In no case shall seller be liable for 

any consequential or incidental damages for breach of this or any 
other warranty, expressed or implied, or upon any other basis of 
liability whatsoever.
Seller's obligation under this warranty shall not include any transporta-
tion charges or costs of installation or any liability for direct, indirect, 
or consequential damages or delay. Seller does not represent that its 
product may not be compromised or circumvented; that the product 
will prevent any personal injury or property loss by burglary, robbery, 

¿

re or otherwise; or that the product will in all cases provide adequate 

warning or protection.
Seller, in no event shall be liable for any direct or indirect damages or 
any other losses occurred due to any type of tampering, whether 
intentional or unintentional such as masking, painting or spraying on 
the lenses, mirrors or any other part of the detector.
Buyer understands that a properly installed and maintained alarm 
may only reduce the risk of burglary, robbery or 

¿

re without warning, 

but is not insurance or a guaranty that such event will not occur or that 
there will be no personal injury or property loss as a result thereof.
Consequently seller shall have no liability for any personal injury, 
property damage or loss based on a claim that the product fails to 
give warning. However, if seller is held liable, whether directly or 
indirectly, for any loss or damage arising under this limited warranty 
or otherwise, regardless of cause or origin, seller's maximum liability 
shall not exceed the purchase price of the product, which shall be 
complete and exclusive remedy against seller.
No employee or representative of Seller is authorized to change this 
warranty in any way or grant any other warranty. 

WARNING:

 This product should be tested at least once a week.

CAUTION

: risk of explosion if battery is replaced by an incorrect type.

Dispose of used batteriess according to local regulations.

Hahoma 14,  Rishon Lezion, ISRAEL

Contacting RISCO Group

UK

  Tel: +44-(0)-161-655-5500

E-mail: [email protected]

ITALY

  Tel: +39-02-66590054

E-mail: [email protected]

SPAIN

  Tel: +34-91-490-2133

E-mail: [email protected]

FRANCE

  Tel: +33-164-73-28-50

E-mail: [email protected]

BELGIUM

  Tel: +32-2522-7622

E-mail: [email protected]

U.S.A

  Tel: +1-631-719-4400

E-mail: [email protected]

BRAZIL

 

 Tel: +55-11-3661-8767

E-mail: [email protected]

CHINA

  (Hu) Tel: +86-21-52390066

E-mail: [email protected]

CHINA

  (SZ) Tel: +86-755-82789285

E-mail: [email protected]

POLAND

 

 Tel: +48-22-500-28-40

E-mail: [email protected]

ISRAEL

 

 Tel: +972-3-963-7777

E-mail: [email protected]

GENERAL DESCRIPTION

English

Max.
1cm

Figure 1

 

 

AUSTRALIA 

  Tel: +1800-991-542 

E-mail: [email protected]

T  

  Shutter pulse       01 - 16

*

 

B

  

A

  

Figure 3

A

  

 

Back bracket

Back side of
transmitter

B

  

Figure 2

T  

C

  

Figure 4

Figure 5

    using 2 mounting screws and back tamper screw (Fig 3C).
    
   
 

2. Spacers are purchased separately (see table above).  

*

 If de

¿

ned

OPERATION MODE

A

  

  

  

Spacer Part No.                   Description

 

RAX73XS0000A  Transmitter spacers x 10, white (5 x 4mm + 5 x 2mm)

RAX73XSB000A  Transmitter spacers x 10, brown (5 x 4mm + 5 x 2mm)

 

 

RAX73MS0000A  Magnet spacers x 10, white (5 x 4mm + 5 x 2mm)

      

 

RAX73MSB000A  Magnet spacers x 10, brown (5 x 4mm + 5 x 2mm)

      

1. It’s best to mount the transmitter on the non-moving part 
    (door/window frame), and the magnet on the moving part. 

B

  

reed switch. In normal operation mode, an alarm is sent when  

a restoral message.

screws (Fig 4B).

3. Optionally, mount spacer(s) for transmitter and/or magnet  
    as required (Fig. 6), positioned between the back bracket  
    and the mounting surface. 

Figure 6

Magnet spacers (10-piece sets):

Transmitter spacers (10-piece sets):

  

p/n: RAX73MS0000A (white) 

   

  

p/n: RAX73MSB000A (brown) 

   

 

 p/n: RAX73XS0000A (white) 

   

  

p/n: RAX73XSB000A (brown) 

   

5 X 4mm

5 X 2mm

5 X 4mm

5 X 2mm

[Optional] [Optional]