![Risco LightSYS Installation And Programming Manual Download Page 84](http://html.mh-extra.com/html/risco/lightsys/lightsys_installation-and-programming-manual_1464244084.webp)
Engineer Programming
Page 84
System: Service Information
Quick Keys
Parameter
Default
Range
Name
Any 16 characters
Enables you to insert and/or edit the name of the ARC from whom service
may be obtained.
Phone
Any 16 characters
Enables you to insert and/or edit the service phone number.
Firmware Update
Note:
The firmware update menu option series is visible only if the IP or GSM module is installed.
Access and configure the parameters in the System Control menu, as follows:
System: Firmware Update
Quick Keys
Parameter
Default
Range
Server IP
firmware.riscogroup.com
Enter the IP address of the router/gateway where the upgrade file is
located.
Server Port
80
Enter the port on the router/gateway where the upgrade file is located
File Name
CMD.TXT
Enter the upgrade file name. for example: /LightSYS/0UK/cpcp.bin
Please contact Customer Support services for the file name parameters
Download File
Select the communication path for the upgrade.
Via IP
Via GPRS
2 Zones
The LightSYS supports up to 32 zones. Each zone can be defined to be a wired zone, a
wireless zones or a bus zone. The attributes for each zone vary according to the zone’s type
(wired, wireless or type of bus zone).