System: Controls: DD243
Quick Keys
Parameter
Default
Range
DD243
Yes
Yes/No
This section refers to controls that apply to DD243 approvals.
Omit Exit/Entry
Yes
Yes/No
YES
: It is possible for the user to omit an Exit/Entry zone.
NO
: An Exit/Entry zone cannot be omitted.
Entry Disable
No
Yes/No
YES
: The alarm confirmation process will be disabled when the entry
time starts.
NO
: The alarm confirmation process will start when the entry time
starts.
Route Disable
No
Yes/No
YES
: The panel disables the entry route zones (EX/EN, EX (OP)/EN,
followers and Final Exit) from participating in the alarm confirmation
process when the entry time starts.
Note
Sequential confirmation can still be established from two confirmed
zones, located off the entry route.
NO
: The entry route zones will participate in the alarm confirmation
process when the entry time starts.
Engineer Reset
Confirmation
No
Yes/No
YES
: An engineer reset confirmation is required in order to reset the
system after a confirmed alarm. The system cannot be set until an
engineer reset confirmation is performed. The reset can be done by
entering the Anti code or entering the installation mode or by
performing an “Engineer reset” from the keypad.
NO
: Any means can be used to set or unset the system (keypad, remote
phone operation etc.).