2-Way Siren
Module
Module Sirène
2-Way Modulo
per sirena
radio
bidirezionale
2-Weg
Sirenenmodul
Model EL-4262
Modèle EL-4262
Modello EL-4262
Modell EL-4262
Contacting RISCO Group
RISCO Group is committed to customer service and product support. You can
contact us through our website (www.riscogroup.com) or at the following
telephone and fax numbers:
International Headquarters:
RISCO Group
14 Hachoma St., 75655, Rishon Le Zion, Israel
Tel: (+972-3) 963-7777, Fax: (+972-3) 961-6584
RISCO Group Limited Warranty
RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal
use for 24 months from the date of production. Because Seller does not install or connect the product and because the product may be used in
conjunction with products not manufactured by the Seller, Seller cannot guarantee the performance of the security system which uses this product.
Seller's obligation and liability under this warranty is expressly limited to repairing and replacing, at Seller's option, within a reasonable time after the
date of delivery, any product not meeting the specifications. Seller makes no other warranty, expressed or implied, and makes no warranty of
merchantability or of fitness for any particular purpose.
In no case shall seller be liable for any consequential or incidental damages for breach of this or any other warranty, expressed or implied, or upon
any other basis of liability whatsoever.
Seller's obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct, indirect, or
consequential damages or delay.
Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any personal injury or property loss
by burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or protection .
Seller, in no event shall be liable for any direct or indirect damages or any other losses occurred due to any type of tampering, whether intentional or
unintentional such as masking, painting or spraying on the lenses, mirrors or any other part of the detector.
Buyer understands that a properly installed and maintained alarm may only reduce the risk of burglary, robbery or fire without warning, but is not
insurance or a guaranty that such event will not occur or that there will be no personal injury or property loss as a result thereof.
Consequently seller shall have no liability for any personal injury, property damage or loss based on a claim that the product fails to give warning.
However, if seller is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of
cause or origin, seller's maximum liability shall not exceed the purchase price of the product, which shall be complete and exclusive remedy against
seller.
No employee or representative of Seller is authorized to change this warranty in any way or grant any other warrant.
CAUTION: This product should be tested at least once a week.
WARNING: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to local regulations.
Introduction
The 2-Way Siren Module EL-4262 is an add-on module that is used to pair RISCO Group’s range of 2-way Sirens (EL4726 and EL4723) to the CommPact and Prime 1-way control panels
Control Panel
Settings
For CommPact Panel
(from version 401.37
and higher):
Input event – Set PGM
Output as ‘SIREN MODULE’
Output event – Set Zone #33
‘LOOP TYPE’ as Normally
Closed
For Prime Panel:
Input event – Set PGM Output
as ‘SIREN’
NOTE: for best performance of the product it is
recommended to install the module outside the
control panel.
DIP Switch Settings
(default *)
Switch
State
Description
1 ON Tamper on
OFF *
Tamper off
2 ON Low battery on
OFF *
Low battery off
3 ON Communication trouble on
OFF *
Communication trouble off
4 ON For Prime
OFF *
For CommPact
NOTE: If switches (1-3) are set to ON the output of the
module will trigger the wired zone on the panel and create an
alarm according to the panel's configuration.
Terminal Wiring and PCB Layout
Antenna
Dip Switch
Tamper switch
Terminal block
Test Button
LED indicator
Wiring knockout
PCB release tab
Registering and Testing the 2-Way Siren
Power-up the module.
Once the Red and Green LEDs are flashing consecutively, send a signal from the
siren by inserting the batteries. If the LED continues flashing Red and Green,
press the tamper on the siren.. Once registered, press the Test button. The Green
LED begins to flash according to the transmission quality (4 flashes – best, 1 flash
– poor). Close the module housing cover to complete registration.
LED
State
Description
Yellow On
Siren Low battery
On
Normal Operation
Green Flashing Testing mode
On
Communication trouble
Red Flashing Siren tamper activated
Intermittent
flashing
Module tamper activated
Red &
green
Flashing
(consecutively)
Registration/ deletion mode
On
Siren Low battery
NOTE: A combination of troubles is indicated by a 3 second steady Red
LED followed by a 3 second blinking Yellow LED
.
Deleting a Siren
1. Open the 2-Way Siren Module and press the Test button for
approximately 7 seconds until the Red and Green LEDs flash
consecutively. This confirms the deletion.
2. Open the siren cover and take out the batteries.
3. Press the tamper switch. While the tamper switch is being pressed insert
the batteries. Within five seconds open the tamper and close it again.
Technical Specifications
Frequency – 868 MHz, 433 MHz, Power – 12VDC
Operating Temperature – -10 – 55°C
RTTE Compliance Statement:
Hereby, Electronics Line 3000 Ltd. declares that this product is in compliance with the
essential requirements and other relevant provisions of Directive 1999/5/EC. The
declaration of conformity may be consulted at
www.riscogroup.com
All rights reserved.
No part of this document may be reproduced in any form without prior written
permission from the publisher
RISCO Group 01/2016