background image

2-Way Siren 
Module 
Module  Sirène 
2-Way Modulo 
per sirena 
radio 
bidirezionale 
2-Weg 
Sirenenmodul 

Model EL-4262 
Modèle EL-4262 
Modello  EL-4262 
Modell EL-4262 

 

 

 

Contacting RISCO Group 

RISCO Group is committed  to customer service and product  support. You can 
contact us through  our  website (www.riscogroup.com) or at the following 
telephone and fax numbers: 
International Headquarters: 
RISCO Group 
14 Hachoma St., 75655, Rishon Le Zion,  Israel 
Tel: (+972-3) 963-7777, Fax: (+972-3) 961-6584

 

RISCO Group Limited Warranty

 

RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal 
use for 24 months from the date of production. Because Seller does not install or connect the product and because the product may be used in 
conjunction with products not manufactured by the Seller, Seller cannot guarantee the performance of the security system which uses this product. 
Seller's obligation and liability under this warranty is expressly limited to repairing and replacing, at Seller's option, within a reasonable time after the 
date of delivery, any product not meeting the specifications. Seller makes no other warranty, expressed or implied, and makes no warranty of 
merchantability or of fitness for any particular purpose. 
In no case shall seller be liable for any consequential or incidental damages for breach of this or any other warranty, expressed or implied, or upon 
any other basis of liability whatsoever. 
Seller's obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct, indirect, or 
consequential damages or delay. 
Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any personal injury or property loss 
by burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or protection . 
Seller, in no event shall be liable for any direct or indirect damages or any other losses occurred due to any type of tampering, whether intentional or 
unintentional such as masking, painting or spraying on the lenses, mirrors or any other part of the detector. 
Buyer understands that a properly installed and maintained alarm may only reduce the risk of burglary, robbery or fire without warning, but is not 
insurance or a guaranty that such event will not occur or that there will be no personal injury or property loss as a result thereof. 
Consequently seller shall have no liability for any personal injury, property damage or loss based on a claim that the product fails to give warning. 
However, if seller is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of 
cause or origin, seller's maximum liability shall not exceed the purchase price of the product, which shall be complete and exclusive remedy against 
seller. 
No employee or representative of Seller is authorized to change this warranty in any way or grant any other warrant. 
CAUTION: This product  should be tested at least once a week. 
WARNING: Risk of explosion if  battery is replaced by an incorrect type. Dispose of used batteries according to  local regulations.

 

      Introduction 

The 2-Way Siren Module  EL-4262 is an add-on module that is used to pair RISCO Group’s range of 2-way Sirens (EL4726 and EL4723) to the CommPact and Prime 1-way control panels

 

 

Control Panel 

Settings

 

For CommPact Panel 
(from version  401.37 
and higher): 
Input     event    –    Set    PGM 
Output  as ‘SIREN MODULE’ 
Output  event – Set  Zone #33 
‘LOOP   TYPE’  as  Normally 
Closed 
For Prime Panel: 
Input event – Set PGM Output 
as ‘SIREN’

 

 

 

NOTE: for best performance of the product it is 
recommended to install the module  outside  the 
control panel.

 

 

DIP Switch  Settings

 

 (default *)  

 

Switch  

State 

Description 

1 ON  Tamper on 

OFF * 

Tamper off 

2 ON  Low battery on 

OFF * 

Low battery off 

3 ON  Communication trouble on 

OFF * 

Communication trouble off 

4 ON  For Prime 

OFF * 

For CommPact 

NOTE: If switches (1-3) are set to ON  the output  of  the 
module  will trigger the wired zone on the panel and create an 
alarm according to the panel's configuration.

 

 

 

Terminal  Wiring and PCB Layout

 

 

 

Antenna

 

 

Dip Switch

Tamper switch

 

 

Terminal block

 

Test Button 

 

LED indicator

Wiring knockout

 

 

PCB release tab

 

Registering and Testing the 2-Way Siren 

 

Power-up the module.

 

Once the Red and Green LEDs are flashing  consecutively, send a signal from  the 
siren by inserting  the batteries. If the LED continues flashing Red and Green, 
press the tamper on the siren.. Once registered, press the Test button.  The Green 
LED begins to flash according to the transmission quality  (4 flashes – best, 1 flash 
– poor).  Close the module  housing  cover to complete registration. 

 

LED  

State 

Description 

Yellow On 

Siren Low  battery 

On 

Normal  Operation 

Green Flashing  Testing mode 

On 

Communication trouble 

Red Flashing Siren tamper activated 

Intermittent 
flashing 

Module tamper activated 

Red & 
green 

Flashing 
(consecutively) 

Registration/ deletion mode 

On 

Siren Low  battery 

NOTE: A combination of  troubles  is indicated by  a 3 second steady Red 
LED followed by a 3 second blinking Yellow  LED

Deleting a Siren 

1.  Open the 2-Way Siren Module and press the Test button for 

approximately 7 seconds until the Red and Green LEDs flash 
consecutively. This confirms the deletion. 

2.  Open the siren cover and take out the batteries. 
3.  Press the tamper switch. While the tamper switch is being pressed insert 

the batteries. Within five seconds open the tamper and close it again. 

Technical Specifications 

Frequency – 868 MHz,  433 MHz, Power – 12VDC 
Operating Temperature – -10 – 55°C 

RTTE Compliance Statement:

 

Hereby, Electronics Line 3000 Ltd. declares that this product is in compliance with the 

essential requirements and other relevant provisions of Directive 1999/5/EC. The 

declaration of conformity may be consulted at 

www.riscogroup.com

 

All rights reserved. 

No part of this document may be reproduced in any form  without prior written 
permission from  the publisher 
RISCO Group   01/2016 

   5IN2138 

E

 

 

 

Reviews: