WS6-M
ADJUSTABLE END STRIPPER
Note: This tool is a manually operated cutting device for polyethylene, (XLPE)cross link polyethylene, and (EPR)
ethylene propylene rubber insulation on 15KV to 46KV cables 22.86mm ( .900”) to 52.07mm (2.030”) in diameter.
OPERATING INSTRUCTIONS
For best results, the end of the cable to be stripped should be cut straight and square using a
hack-saw or curved jaw cable cutters.
Step 2.
(Fig. 2) To insert the bushing into the WS6-M, line up rib
on the bushing with the slot on the WS6-M housing. Raise the
cutting blade by depressing outer end and insert the bushing until it
locks into place.
Step 3.
(Fig. 3) To adjust the stop bar for desired length of
conductor exposure, loosen set screw located on the end of
the tool body directly above the stop bar. Adjust the stop
bar to the desired length of insulation to be stripped and
tighten the set screw.
Step 4.
(Fig. 4) To strip the insulation, insert the cable into the
WS6-M until it comes in contact with cutting edge of the blade.
Always check the blade position with respect to the conductor,
before stripping the insulation.
Fig. 4
Fig. 3
Fig. 2
RIB
SLOT
PRESS
CUTTING
BLADE
GRADUATED
STOP BAR
CABLE
BLADE CUTTING
EDGE
SET SCREW
Warning
!
This tool is not protected against electrical shock!
Always use
OSHA/ANSI
or other industry approved eye protection
when using tools. This tool is not to be used for purposes other than intended. Please read and understand instructions before using
this tool.
Step 1.
(Fig 1) Check the bushing by sliding it over
polyethylene insulation (Fig 1A) or semi-con over EPR
insulation (Fig. 1B). The bushing should fit snugly and
still rotate easily on the cable.
We recommend the use of
lubricant be used on the semi-con over EPR cable.
Fig. 1A
Fig. 1B
Fig. 1