UPM100 User Guide

UPM100

Optical Power Meter

User Guide

Summary of Contents for Miller UPM100

Page 1: ...Page 1 UPM100 User Guide UPM100 Optical Power Meter User Guide...

Page 2: ...ents Introduction 3 Device Overview 3 Important Safety Information 4 Setting a Reference 5 Basic Testing 5 Maintenance 6 Integration with Windows InSpec 7 Integration with Android InSpec Certification...

Page 3: ...If you are looking for a low cost device capable of saving and reporting take a look at the RP460 or UPM100 if you want to use IOS or Android with bluetooth Introduction USB Port The UPM100 uses this...

Page 4: ...toward non reflective surfaces to prevent reflection of laser Electric Shock Hazard Pay attention to proper battery polarity Do not mix battery types or manufacturers Do not open the unit with the ex...

Page 5: ...nnect the UPM100 and companion light source as shown below Ensure the unit is in dBm and you are reading the correct output power for the laser LED you are using Ripley Lasers are calibrated at 5 or 8...

Page 6: ...l Connector Interface The UPM100 is not a standalone device The UPM100 is not a standalone Power meter To set reference view absolute or relative power or to save readings requires that you either con...

Page 7: ...B is clicked you can select a different mode the wavelength is changed the same way Save Click to save the current reading The reading will appear in the data window on the left side of the screen Del...

Page 8: ...Page 8 UPM100 User Guide The saved data that is saved can be edited for final reporting in the Reports tab Delete Delete selected reading s Edit Edit multiple readings...

Page 9: ...on the computer keyboard and click multiple readings to select multiple readings for editing To select a range of readings click the first reading in the range hold the Shift key on the computer keyb...

Page 10: ...which can be used in the future When using a Custom option enter the color codes in the white space on the left side of the window Each line represents an indexed location Click Save when finished The...

Page 11: ...is usually set to 0 A maximum of 3 is standard for most fiber tests Set Min and Max to any values as needed then click Apply Any readings which fall within the Min Max range provided will be given a...

Page 12: ...to Defaults to return to this arrangement of information Enter all info as needed and click Save to have the information appear on reports The Ripley Miller logo will appear on reports Click Browse to...

Page 13: ...to use the device with that device Open the InSpec app on your Android device Touch the OPM Page button to access the OPM page of the app If the UPM100 is connected it will either detect and begin st...

Page 14: ...uched Data is NOT saved on the UPM100 Delete Selected Delete the selected data row Edit Selected Change the Name ID of the selected data row SetRef Touch this button to set the reference when in dBm m...

Page 15: ...ecting it and touching Delete Selected To set PASS FAIL limits for testing touch the icon in the top right corner of the screen and select OPM Settings The currently set Min and Max will be displayed...

Page 16: ...100 data stream will disconnect automatically when the Reports screen is accessed To restart the data stream and continue testing follow the connection instructions on page 19 Delete and or edit any r...

Page 17: ...PM100 comes calibrated and should be recalibrated every 2 years Included with the UPM100 is a calibration certificate and free recalibration within 2 years of the date of purchase To start the calibra...

Page 18: ...erence to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television rece...