COMMAND D:
21100040:0;
COMMAND D:
Stop streaming (Register 0040
H
):
ADDR
= 21
H
: Reply required from instrument #1
CMD
= 10
H
: Execute
REG
= 0040
H
: Streaming start register
DATA
= 0: Stop streaming
RESPONSE D:
81100040:0000;
RESPONSE D:
Instrument #1 will stop streaming on change.
18.4
rinCMD Registers
Name
Address
Type
R
W
Description
Software Model
0003
H
string
A
N
Returns software loaded (e.g. C520)
Software Version
0004
H
string
A
N
Returns software version (e.g. v1.0.0)
Serial Number
0005
H
uint32
A
N
Returns instrument serial number
User Defaults
0007
H
execute
N
F
Set the indicator to default settings.
Values are: 0: Default all settings (user,
runtime, calibration, network) 1: Default
user database except calibration 2: Default
runtime database 3: Default calibration 4:
Default network settings 5: Default
licensing database
Keyboard Buffer
0008
H
uint8
N
A
Adds a key to the key buffer. The short
press key codes are shown below. For long
presses, set the most significant bit to 1.
Key codes are:
11: Zero key
12: Tare key
13: Gross/Net key
14: F1 key
15: F2 key
16: F3 key
32-40: I/O 1 - I/O 8
LCD Bitmap
0009
H
string
A
N
Returns the LCD bitmap
LCD Display Mode
000D
H
execute
N
A
Change the display mode. 0 for system
control, 2 for register control.
Save settings
0010
H
execute
N
A
Save settings and re-initialise
OIML Calibration Counter
0012
H
uint32
A
N
OIML Calibration Counter
NTEP Calibration Counter
0013
H
uint32
A
N
NTEP Calibration Counter
NTEP Configuration Counter
0014
H
uint32
A
N
NTEP Configuration Counter
Trade Enable
0015
H
uint8
A
N
Is the indicator suitable for trade use. 0 =
No, 1 = Yes. Always returns 1, as all
C520s are suitable for trade use.
Reset
0016
H
execute
N
A
Reboot the indicator
Set full permissions
0019
H
uint32
F
A
Write full passcode to elevate permissions
Set safe permissions
001A
H
uint32
S
A
Write safe passcode to elevate permissions
ADC Sample Number
0020
H
uint32
A
N
Read current sample number since last
power on
78
C500-600-2.0.3
Summary of Contents for C500 series
Page 1: ...C500 Series Digital Indicator Reference Manual ...
Page 54: ...8 3 Custom Format Tokens 8 3 1 Formatting 49 C500 600 2 0 3 ...
Page 56: ...230 Send time in format hh mm ss 231 Send Date in format dd mm yyyy 51 C500 600 2 0 3 ...
Page 123: ...118 C500 600 2 0 3 ...
Page 182: ...177 C500 600 2 0 3 ...