IBF - Slimfire 25
- 10 -
Issue 5 - ©Rinnai
3. Install Rinnai Zero Clearance Box (ZEROR)
•
‘Zero clearance’ means the panels of metal from the
zero clearance box can be in contact with any
combustible material.
•
The hearth surface must be flat and level to support the
zero clearance box.
If the zero clearance box base is not properly
supported noise and vibration may result.
Kit contains:
- Zero Box
- Supporting Plinth
- Complete decorative Surround
- Installation Instructions
- Complete decorative Surround
- Installation Instructions
Steps for Installation:
1. Determine the preferred location of the heater.
•
Check roof space for any flue obstructions.
2. Construct frame in accordance with the dimensions
shown:
685mm
675mm
370 mm