• Current AS/NZS 3000
All applicable local rules and regulations including local OH&S requirements
Manufacturer’s Installation Instructions
This system must be installed, commissioned and serviced by an Authorised Person.
Page 1: ... AS NZS 3000 All applicable local rules and regulations including local OH S requirements Manufacturer s Installation Instructions This system must be installed commissioned and serviced by an Authorised Person ...
Page 2: ... 6 6 8 9 10 11 12 14 16 16 2 Commissioning Packing list Operation Notices Care and Maintenance Troubleshooting Installation Guide Selection of installation location Installation of the indoor unit Installation of the outdoor unit Pipe connection Electrical connection ...
Page 3: ...hey do not play with the appliance Stop operation and cut off the main power in storm or hurricane Operation with windows opened may cause electric shock L ig h tn in g The air conditioner must be earthed Incomplete grounding may result in electric shock Do not connect the earth wire to the gas pipeline water pipeline lightning rod or telephone earth wire Cut off the power supply switch Isolate po...
Page 4: ... time and make food fresh otherwise abnormal use will cause damage 9 It is forbidden to let children and the disabled use air condition without other adult supervision 10 Open windows frequently after using air condition for a long time 11 If the equipment emissions cannot meet the technical requirement of IEC 61000 3 3 Following Attention should be take care Attention Through poor conditions of t...
Page 5: ...ly differences to the promotion information and actual appliance Please refer to the appliance purchased Name of Each Part Indoor Unit Outdoor Unit 1 Front panel 2 Air filter 3 On Off button 4 Louver 5 Signal receiver 6 Supply cord if installed 7 Remote controller 8 Drain hose 9 Refrigerant gas liquid pipe 10 Cut off valve 11 Air outlet cover Outdoor Unit Air inlet Air outlet Air inlet Air outlet ...
Page 6: ... air conditioner remote controller instruction for how to adjust horizontal air flow Adjusting air flow direction 1 orizontal air flow manually Adjusting h Remote controller operation See air conditioner remote controller instruction 2 Adjusting vertical air flow direction up down Refer to air conditioner remote controller instruction for how to adjust vertical airflow direction through adjusting ...
Page 7: ...er referring to page to 6 Cleaning for how to operate 5 Check to see whether the outdoor install bracket is damaged If yes please contact our Service center locally Checking before operation To prevent injury and property damage Please pay attention to these following before operating the air conditioner 5 Cooling Heating Indoor Outdoor Indoor Outdoor 18 43 A pply to constant speed 30 7 A pply to ...
Page 8: ...nd then take it out 2 Use a vacuum cleaner or wash them with water then dry it in the shade 3 Reinsert the air filter into the indoor unit until being entirely fixed then close the front panel 1 Select FAN operation mode make the air conditioner run a long time to dry 2 Turn off the air conditioner and cut off the power supply 4 Clean air filters and other parts 3 Take out the batteries from the r...
Page 9: ...operation Because the air of the room is cooled down rapidly by the cold wind and it looks like fog This is generated due to moisture in defrosting process Low noise can be heard during operation A low hissing sound is caused by the refrigerant flowing A low squeak sound is caused by the expansion and contraction of plastic due to temperature Cooling Heating efficiency is not good Is the setting t...
Page 10: ...cuit should have leakage protector and switch of which the capacity should be more than 1 5 times of the maximum current If your air conditioner is not fitted with a supply cord and a plug a If your air conditioner is permanently connected to the fixed wiring and have a leakage current that may exceed 10 mA Guide for customer Notices 1 The air conditioner must be installed on strong supports or su...
Page 11: ...culation Convenient to adopt measures to reduce noises Do not install near doorways Make sure to have the distance between the ceiling wall furniture and other obstacles 2 meters high above the floor In case that you put up a canopy to protect it from weather and sun exposure pay attention not to restrict air flow through condenser coil Do not place animals or plants near the installation location...
Page 12: ...own in the following table Pull out the indoor unit pipes after pipe Spanner Remove the base support foam in one side before installation Foam Connection pipe Cable Hang the indoor unit to the board and make sure the machine is in the middle of the board Pushing the machine towards the left down and right down side of the installation board until the hangers enters tightly the grooves it makes cli...
Page 13: ...e Put a cup of water into groove Check whether the water flow through the water discharge hole Bolt Bolt Vertical airflow direction plate Front frame Pull down the front frame towards your and take off the front frame Installation of the outdoor unit The outdoor unit must be firmly fixed to avoid falling in the strong wind Install on the cement base the drawing below If it will be installed at sea...
Page 14: ...gside the wall and fix them to the wall with clips These steps are usually adopted when outdoor unit is installed below the indoor unit Use sealing tape to cover the small leaks on the external ring of the pipe Wrap up with tape Pipes Water discharge pipe Connection wire Control panel cover Connection wire Round in this shape to prevent water entering the electrical parts Round shape Round shape U...
Page 15: ... open the handle Lo of the manifold valve 4 Operate the vacuum pump to evacuate After starting evacuation slightly loose the flare mut of the Lo valve on the gas pipe side and check that the air is entering Operation noise of the vacuum pump changes and a compound meter indicates 0 instead of minus 5 After the evacuation is complete fully close the handle Lo of the manifold valve and stop the oper...
Page 16: ...anel if the indoor unit is fitted with the signal wire please detach the mid frame and insert the signal wire through the bottom frame then connect the signal wire quick plug of the indoor s to the outdoor s Electrical connection Open the front panel inset the connection cables from the base of the air conditioner conneting to the terminal board in order according to the graph using the pressing b...
Page 17: ...constant speed L S N L S N L S N L S N Cover Cover 1 2 L N 1 2 L N More than 5mm More than 5mm Electric bracket Electric bracket Electric bracket Grounded wire Grounded wire Grounded wire Terminal board Pressing board Pressing board Pressing board Terminal board Terminal board Terminal board 5 2KW 7 0KW Electric bracket Pressing board Connec tion cables Connec tion cables Connec tion cables Connec...
Page 18: ...e outlet air temperature subtract from inlet s gives more than 10 Test running Discharged air Packing list Please check the following attach carefully if part attach isn t useful please take care of it Packing list of the indoor unit Packing list of the outdoor unit NO Name Unit Quantity 1 2 3 4 5 6 Indoor unit Remote Controller Remote wall bracket AAA Battery Energy Rating Label User Manual SET P...
Page 19: ......