Installation Manual
HEATER LOCATION
GAS SUPPLY
ELECTRICAL SUPPLY
MANTLE INSTALLATIONS
The gas supply terminates inside the heater and enters the appliance
from the rear. To ensure correct positioning, terminate the gas supply
so that it is 175mm from the front of the enclosure opening.
Fit the supplied adapter and flexible hose to the gas supply prior to
moving the heater into the enclosure.
Gas pipe sizing must consider the gas input to this
appliance as well as all other gas appliances in the
premises. The gas meter and regulator must be
specified for the total gas rate. Suitable sizing chart
such as the one in AS/NZS 5601 should be used.
PURGING THE GAS SUPPLY: All foreign materials
such as filings must be purged from the gas supply,
as they may cause the gas control valve to
malfunction.
This heater has a power cord with a three pin plug supplied. The
power cord passes through the gap at the rear left of the appliance.
Rinnai recommend the heater be plugged into a 240V, 10A earthed
power point. The power point must be a maximum of 1500 mm to the
side of the heater (it must not be above the heater). Alternatively the
appliance can be direct wired if the power supply is to be concealed.
Consult a qualified electrician if direct wiring is
required as it must comply with the requirements of
AS/NZS 5601 and AS/NZS 3000 and any other
relevant local regulations.
A mantle is permitted providing the following clearances are met.
* 75 mm is the minimum clearance required for access to the heater controls and to allow
cleaning / servicing.
175 mm
175 mm
FRONT OF
ENCLOSURE
Consumer Pipe
Consumer Pipe
Flexible Pipe (supplied)
Flexible Pipe (supplied)
Adapter (supplied)
Adapter (supplied)
REAR OF
ENCLOSURE
Gas supply pressure
to be 1.13 to 3 kPa
IMPORTANT
IMPORTANT
75*
25
45°
250
200
75*
25
150
45°
100
Top View
Side View
Heater Fascia
Heater Fascia
Mantles are allowed within the shaded areas
IMPORTANT