12. Component Circuit Value Table
CN
WIRE COLOUR
SURGE PROTECTOR
D
1
B-Br
AC207~264V
R-B
DC11~13V
OPERATE ELECTRICITY
Gy-O
DC11~13V
CONTROL ELECTRICITY
BELOW DC1V (LIMITER ON)
DC4~6V (LIMITER OFF)
BELOW DC1V (LIMITER ON)
DC4~6V (LIMITER OFF)
DC12V (OPERATING DC2~6V) OPERATE CONDITION
15~35
WATER CONTROLLER
A
1
Bk-Bk
DC11~13V
R - Bk
DC11~13V
Y - Bk GND
DC4~7V (PULSE 17~460Hz)
R - Bk
DC6~45V
Y - Bk
DC11~13V
W-Bk GND
DC6~45V (33~400 Hz)
Y - BODY EARTH
AC5~150V
AFTER IGNITION
Y - FLAME ROD
OVER DC1μA
FLAME CONDITION
MODULATING VALVE
E
2
P-P
DC2~15V
67~81
OUTGOING THERMISTOR
G
5
W-W
AIR THERMISTOR
G
6
W-O
THERMAL FUSE
G
1
E
3
R-R
BELOW 1
IGNITER
C
1
Gy-Gy
AC207~264V
MAIN SOLENOID VALVE
F
1
P-Bk
DC11~13V
37~43
SOLENOID VALVE 1
F
2
Y-Bk
DC11~13V
37~43
SOLENOID VALVE 2
F
3
B-Bk
DC11~13V
37~43
SOLENOID VALVE 3
F
4
Br-Bk
DC11~13V
35~41
15° C … 11.4~14.0 k
30° C … 6.4~ 7.8 k
45° C … 3.6~ 4.5 k
60° C … 2.2~2.7 k
105°C …0.6~0.8 k
FLAME ROD
HEAT EXCHANGER
OUTGOING THERMISTOR
G
4
W-P
COMBUSTION FAN
B
1
FLOW
CHART NO.
MEASUREMENT POINT
Gy-Y
Gy-Br
WATER FLOW
CONTROL DEVICE
G
6
E
1
FULL OPEN POSITION
FULL CLOSE POSITION
G
3
WATER FLOW SENSOR
Br-W
O-W
Y-W
R-W GND
COMPONENT
NORMAL VALUE
NOTE
ON 2.7 L/min (30Hz)
OVER 1800PULSE/min
OFF 2.0 L/min (20Hz)
BELOW 1200PULSE/min
BY-PASS FLOW
CONTROL DEVICE
H
1
:
:
:
:
:
:
:
:
:
:
:
:
1
2
17
3
4
5
6
8
9
10
11
12
13
14
15
16
17
Summary of Contents for REU-V2632FFUG
Page 1: ...DRDAFT SERVICE MANUAL To Suit Models Does NOT Suit Other Models REU V2632FFUG REU VM2632FFUC...
Page 15: ...Infinity REU V2632FFUG HD200i REU VM2632FFUC 10 Issue 1 16 12 09 Rinnai 7 Cutaway Diagram...
Page 33: ...Infinity REU V2632FFUG HD200i REU VM2632FFUC 28 Issue 1 16 12 09 Rinnai...
Page 47: ...Infinity REU V2632FFUG HD200i REU VM2632FFUC 42 Issue 1 16 12 09 Rinnai...
Page 48: ...Infinity REU V2632FFUG HD200i REU VM2632FFUC 43 Issue 1 16 12 09 Rinnai...
Page 49: ...Infinity REU V2632FFUG HD200i REU VM2632FFUC 44 Issue 1 16 12 09 Rinnai...