Infinity REU-2007,2008,2408,2424
- 36 -
©Rinnai
)*24
Before carrying out checks marked #, remove power cord from wall plug.
Wiring diagram is on page 35.
Appliance will to operate (even remote control fails to operate)
1)
Is the fuse blown?
Fuses are located in plastic holders in
the main harness, on the lower right
hand side of the appliance
Check fuse
a. Remove 240V plug from socket.
b. # Measure resistance to check the electric
fuse (3A).
Normal:
less than 1
If normal, proceed to check item 2) below.
Faulty:
Replace fuse (5A)
If it blows again, investigate cause of short
circuit.
2)
Is the main transformer normal?
Check the transformer.
a. Measure the voltage in between the red
wires of the relay connector (A
1
).
Normal:
AC90 ~ 110 V / 15 ~ 21
If normal, check 2 below.
Faulty:
Check for AC 90 ~ 110 V on the
PCB terminal J
black ~ black
b. Check voltages below at upper PCB
connector A.
Normal:
orange -orange
AC 13 ~ 30V / 1.4 ~ 1.8
brown - grey
AC 30 ~ 50V / 6 ~10
yellow - grey
AC 180 ~ 220V / 0.4 ~ 0.6
If normal, check 3 at top of next page.
Faulty:
Replace the transformer.
Ω
Ω
Ω
Ω
Ω
Summary of Contents for REU-2007W
Page 1: ...INFINITY...
Page 8: ...Infinity REU 2007 2008 2408 2424 3 Rinnai 1 2 Note All dimensions are in mm...
Page 14: ...2 4 9 9...
Page 15: ......
Page 16: ...Infinity REU 2007 2008 2408 2424 11 Rinnai 2 4...
Page 31: ...Infinity REU 2007 2008 2408 2424 26 Rinnai 3 A A 6 4 8...
Page 32: ...Infinity REU 2007 2008 2408 2424 27 Rinnai 4 2 A Normal Combustion Sequence...
Page 62: ...Infinity REU 2007 2008 2408 2424 57 Rinnai 5 2 4...
Page 63: ...Infinity REU 2007 2008 2408 2424 58 Rinnai...
Page 64: ...Infinity REU 2007 2008 2408 2424 59 Rinnai...