Quick Recovery Electric (QRE) 

Operation & Installation Manual

Models:

QRESS80L336 
QRESS80L348
QRESS315L336
QRESS315L348
QRESS315L360

Summary of Contents for QRESS315L336

Page 1: ...Quick Recovery Electric QRE Operation Installation Manual Models QRESS80L336 QRESS80L348 QRESS315L336 QRESS315L348 QRESS315L360...

Page 2: ...3000 AS NZS 3500 4 Local Regulations and Municipal Building Codes including local OH S requirements This appliance must be installed maintained and removed by an Authorised Person For continued safet...

Page 3: ...Dimensions 11 Table 2 Ratings Other Specifications 11 Installation Configurations 12 Hot Water Plumbing System Example Multiple Installation 12 Hot Water Plumbing System Example No TLD 13 Hot Water Pl...

Page 4: ...TR Valve 17 Expansion Control Valve ECV 17 Pressure Limiting Valve PLV 17 Relief Valve Drain Lines 17 Electrical Connections 18 Commissioning 19 Wiring Diagram 80L 19 Wiring Diagram 315L 20 To fill tu...

Page 5: ...le materials near this appliance This appliance is NOT suitable for use as a spa pool or swimming pool heater WARNING NOTICE TO VICTORIAN CONSUMERS This appliance MUST BE installed by a person license...

Page 6: ...is too hot Always Test the temperature of the water with your elbow before placing your child in the bath also carefully feel water before bathing or showering yourself Supervise children whenever th...

Page 7: ...son It is normal for the PTR valve to release a small quantity of water through the drain pipe during heating If the valve dribbles or leaks continuously try easing the valve gear for a few seconds Th...

Page 8: ...ds and a volume of water sufficient for daily usage is heated during the set period and stored The Off Peak supply is usually cheaper Electricity supply types and tariffs vary according to the local e...

Page 9: ...riction in the hot tap or failure of the cold water supply to the heater Check for water flow at the other hot taps and that the cold water isolation valve is fully open High electricity bills If you...

Page 10: ...t 3 6kW Includes Gasket 80 or 315 L 95110046 Element 4 8kW Includes Gasket 10003735 Element 6 0kW Includes Gasket 315 L only 10003743 3 Terminal Block 80 or 315 L 26401708 4 Thermostat R SH ADJ 60 80...

Page 11: ...A Cylinder Rated Pressure kPa PTR Valve Rated Pressure kPa ECV Rated Pressure kPa ECV Fitted Fit PLV if mains pressure exceeds kPa Recommended PLV pressure rating kPa QRESS315L336 3 6 15 850 850 700...

Page 12: ...equal length and plumbed see example figure above to ensure pressure drops are balanced For multiple systems and tanks ensure the connecting pipework is configured to balance system pressure drop B B...

Page 13: ...ating Valve Isolating Valve PLV ECV OR WATER HEATER Non return Valve COLD SUPPLY Non return Valve Non return Valve WATER HEATER Temperature Limiting Device TLD Non return Valve PTR VALVE Supplied TO D...

Page 14: ...RETURN PIPE WORK WITH TLD COLD SUPPLY Isolating Valve ECV TO DRAIN Non return Valve PLV KITCHEN LAUNDRY NON TEMPERED SUPPLY BATHROOM ENSUITE TO DRAIN PTR VALVE Supplied WATER HEATER Not Supplied Non r...

Page 15: ...result of water leakage the water heater MUST BE installed with a safe tray overflow tray and drain Construction installation and draining of the safe tray MUST comply with local regulatory requiremen...

Page 16: ...Installation Configurations WARNING Valves with pressure ratings other than specified MUST NOT be used An isolation valve and non return valve MUST BE fitted in the cold water supply to the water hea...

Page 17: ...ve outlet in accordance with the section Relief Valve Drain Lines on the bottom of page 17 The valve body MUST BE insulated in accordance with local regulatory requirements and AS NZS 3500 4 to optimi...

Page 18: ...cal cable connections to the water heater Electrical cable entry to the water heater is via a 25mm hole provided beneath the front cover fitting of an approved M25 weatherproof cable gland at the elec...

Page 19: ...Single Number of Throws Single Dial Colour Pink Temp Range 60 to 80 C Dial Set At 70 C Cut Off 60 C 3 Differential 8 C 4 Reset Manual 3 1 4 5 2 ST1205113 RESET 3 1 4 5 2 ST1205113 RESET 3 1 4 5 2 ST12...

Page 20: ...3 RESET 3 1 4 5 2 ST1205113 RESET L1 L2 L3 N 1 2 3 Active Neutral Active Active Neutral Earth Neutral Thermostat Specifications ST1205113 Number of Poles Single Number of Throws Single Dial Colour Pin...

Page 21: ...now be forced out of the taps 3 Close each tap when water runs freely without air bubbles 4 Check all plumbing connections and pipe work for water leaks 5 Connect the water heater to the electricity s...

Page 22: ...Rinnai 22 SS QRE HW IM NOTES...

Page 23: ...Rinnai 23 SS QRE HW IM NOTES...

Page 24: ...0 340 Cost of a local call higher from mobile or public phones For further information visit www rinnai com au or email enquiry rinnai com au Rinnai has a Service and Spare Parts network with personne...