background image

To Suit Models:
Infinity XR 32
Infinity XR26 Plus
Infinity XR26
Infinity XR24
Infinity XR20 Plus
Infinity XR20
Infinity XR18
Infinity XR16
Infinity XR26i
Infinity HD250
Infinity HD250i
Infinity HD200
Infinity HD200i
Efficiency24

Operation / Installation

Manual

How to use and install Rinnai continuous flow water heaters

This appliance shall be installed in accordance with:

• Manufacturer’s Installation Instructions

• Current AS/NZS 3000, AS/NZS 3500 & NZS 5261

• Local Regulations and Municipal Building Codes

This appliance must be installed, serviced and removed by an Authorised Person.

Summary of Contents for Infinity HD250

Page 1: ...ity HD200 Infinity HD200i Efficiency24 Operation Installation Manual How to use and install Rinnai continuous flow water heaters This appliance shall be installed in accordance with Manufacturer s Ins...

Page 2: ...MC 100V 9 HOW TO USE A SINGLE DELUXE WATER CONTROLLER 9 TURNING ON THE CONTROLLER 9 SETTING THE CLOCK 9 SETTING THE SOUND VOLUME 10 ADJUSTING TEMPERATURE 10 DELUXE BATHROOM WATER CONTROLLERS 11 ABOUT...

Page 3: ...r temperatures above 55 C can cause severe burns instantly and may even result in death Those most at risk are children disabled elderly and the infirm Hot water at 65 C a very common hot water temper...

Page 4: ...urned OFF and only turned ON again when the temperature falls below the selected temperature The burner lights automatically when the hot water tap is opened and goes out when the tap is closed IGNITI...

Page 5: ...tandard equipment on all LPG models and is available as an optional extra on all natural gas models If natural gas units are installed into areas where freezing conditions are experienced the optional...

Page 6: ...r at the outlet There is no need to turn the water controller s off after use However if you prefer to turn the water controller s off selected temperatures to a maximum of 50 C will be stored in the...

Page 7: ...re young children and the infirm are concerned Rinnai continuous flow water heaters allow you to control the temperature of your hot water to safe levels Water temperatures above 55 C can cause severe...

Page 8: ...via the kitchen water controller Contact Rinnai for more details These temperatures are suggestions only You may find higher or lower temperatures more comfortable Maintaining lower temperatures helps...

Page 9: ...K WATER TEMPERATURE BEFORE USE A parent or carer should always check the temperature before a child is placed in contact with hot water see page 5 Whilst hot water outlets are open the set temperature...

Page 10: ...n Use indicator will illuminate on the water controller Once the hot water is running if the set temperature is either too hot or cold press the Hot water temp or buttons until the desired temperature...

Page 11: ...s this may cause damage Clock Hour Min Vol Hot water temp 00 00 ON OFF MC 70 1A Transfer Sound Cooler Hotter Bath Hot water temp Used to switch the water heater on and off Used to transfer control pri...

Page 12: ...Monitor To operate the hot water unit open any hot water tap This will automatically light the burner providing hot water The red flame of the water heater In Use indicator will illuminate on the Wate...

Page 13: ...ND VOLUME BUTTON SPEAKER Used to select water temperature TEMPERATURE CONTROL BUTTONS Used to select Shower Saver Bath Fill function SHOWER SAVER BATH FILL BUTTON Indicates the selected hot water temp...

Page 14: ...set individually To do this press the Sound Vol Button located behind the flip panel once The default voice prompt sound volume is medium each subsequent press of the Sound Vol Button will cycle thro...

Page 15: ...ol or buttons that are located directly below the Shower Bath temp buttons located behind the flip panel The selected volume is displayed at the bottom of the controller monitor numerically and graphi...

Page 16: ...ath Fill button Follow the voice prompt instructions When Shower Saver Bath Fill Operations Finishes Once the shower saver bath fill operation finishes the following events will occur 1 The flow from...

Page 17: ...ntake or flue blocked Service Call 11 No ignition No gas supply Check gas is turned on at water heater and gas meter or cylinder 12 Flame Failure Low gas flow Check gas is turned on at water heater an...

Page 18: ...arranty claim 5 Servicing of the product is to be carried out by a Rinnai authorised service centre Extended Warranty for Rinnai Infinity Heat Exchanger The warranty on heat exchangers in Rinnai infin...

Page 19: ...there is no fault with the water heater and the issue is related to the plumbing installation or due to the failure of water electric or gas supplies 3 Where the water heater has failed directly or i...

Page 20: ...TION 24 INSTALLATION 24 INTERCONNECTION OF CONDENSATE DRAIN LINES 25 COMMON STACK DISCHARGE 25 TUNDISH DRAIN LINES 25 AREAS SUBJECT TO FREEZING 25 WATER CONTROLLER INSTALLATION 26 RINNAI WATER CONTROL...

Page 21: ...ls This appliance is designed for Indoor installation only It may be installed Outdoors in an enclosure if the requirements of NZS5261 are satisfied An enclosure is defined as a compartment enclosed a...

Page 22: ...r gas appliances in the premises The gas meter and regulator must be specified for this gas rate An approved sizing chart such as the one in NZS5261 should be used Water pipe sizing and layout should...

Page 23: ...ge Table 1 If the appliance is to deliver water primarily for the purposes of personal hygiene in an early childhood centre primary or secondary school nursing home or a similar facility for the care...

Page 24: ...non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation Space heaters up to 50 MJ h input Other gas appliances up to 50 MJ h input Gas appliances over...

Page 25: ...utlet from base 42 42 42 Gas Fitting Diameter 20 20 20 Cold Fitting Diameter 20 20 20 Hot Fitting Diameter 20 20 20 M N REU VM2630WD REU VM2024WD BC 70 2A MC 70 2A MC 91 2A 90 120 83 20 20 B D C M 355...

Page 26: ...tions earth stakes copper pipes concrete paths or into a pond INSTALLATION a The drain line MUST NOT discharge onto electrical connections earth stakes copper pipes concrete paths or into a pond b The...

Page 27: ...e common stack directly connected to a fixture trap and installed in connection with any adjacent soil or waste stack b The discharge point of the common stack is such that any discharge is readily vi...

Page 28: ...ng is available from Rinnai FITTING THE UNIVERSAL WATER CONTROL MC 91 2A 1 Determine the most suitable position for the water controller 2 Drill 3 holes as shown in Fig 1 two for the securing screws a...

Page 29: ...tchen controller to enable selection of temperatures higher than 50 C STEP 1 For the controller in the KITCHEN only press and hold the Transfer and On Off buttons simultaneously Fig 7 until a beep is...

Page 30: ...er to the wall using the approriate fixings as shown in Fig 4 7 Remove the protective plastic film from the controller face as shown in Fig 4 8 Replace the face plate and close the flip panel If the c...

Page 31: ...cable connector at the base of the appliance 3 Swing the cable connector door open and thread the cable through the weather seal of the cable access hole in the direction shown allowing sufficient cab...

Page 32: ...stallation 9 Close hot water taps including the shower 10 Inspect and clean the strainer located on the cold water inlet connection This procedure may need to be repeated to ensure the strainer remain...

Page 33: ...wn the customer how to operate the Temperature Controllers If fitted Have you explained to the Customer the Benefits of Controllers if not fitted and that they can be added later Have you explained to...

Page 34: ...ater heater installation Basically the covers are designed to hide the plumbing pipework and valves These are particularly popular in installations where the unit is permanently visible to the occupan...

Page 35: ...uiries 0800 746624 0800 RINNAI Installer Enquiries 0800 86746624 0800 TORINNAI Customer Contacts PO Box 24068 Royal Oak Auckland Email info rinnai co nz www rinnai co nz 691 Mt Albert Road Rinnai New...