6.1 TECHNICAL CHARACTERISTICS
TECHNICAL DATA
SHIMANTO 110
Power supply
V/Ph/Hz
220-240/1/50
Water tank real capacity
L
110
Heating capacity
W
850* (+1500**)
Rated power input
W
236* (+1500**)
Nominal current
A
1,14* (+6,5**)
SCOP
DHW
(ERP) ***
W/W
3,01
Max power input
W
400 (+1500**)
Max current
A
1,81 (+6,5**)
Heating time with cold tank (***)
h:min
6:53
Stand-by power input (***)
W
13,4
Max. outlet water temperature
(without E-heater operation)
°C
60
Max water temperature **
°C
70**
Minimum temperature for starting
°C
10
Working ambient temperature
°C
-5 ~ +43
Refrigerant max. discharge pressure
bar
25
Refrigerant max. suction pressure
bar
0,2
Refrigerant type
R134a
Refrigerant GWP
1430
Refrigerant charge
g
650
Amount fluorinated greenhouse gases
tCO
2
eq
0,93
Compressor
Type
Rotary
Oil (type)
68HES-H
Oil (q.ty)
376 ml
Fan motor
Tipo
AC
W
20
Nominal air flow
m3/h
300
Available static pressure
Pa
60
Air flow at 60 Pa
m3/h
170
Duct diameter
mm
DN 125
Max allowed pressure water side
bar
8
Relief valve setpoint (to install externally)
Bar
6
Material of of the inner surface of the tank
S235JR with double-layer vitrification
Auxiliary electric heater
kW
1,5
Electronic expansion valve
yes
Magnesium anode
yes
Material of the heat pump exchanger (condenser)
Copper
Chilled water input
inch
G 1/2 ” male
Hot water outlet
inch
G 1/2 ” male
Condensed water outlet
Flexible plastic tube Ø18 mm
Drainage
inch
To be installed externally
Power cable length
m
1,5
IP protection class
IPX1
Net dimensions LxHxW
mm
500x520X1406
Packing Dimensions
mm
550x550x1460
Net Weight
Kg
72,0
Weight with full tank
Kg
182
Gross Weight
Kg
84,0
Sound power ****
dB (A)
48,5
NOTE:
* Heating capacity, power input based on the following conditions:
- ambient temperature 20°C, water temperature from 15°C to 55°C (obtained results by internal laboratory tests
based on the uniform reintegration of the tank temperature).
** In relation to the auxiliary electric heater. During the anti-legionella cycle, the temperature is raised to 70°C by the
electric heater.
*** Obtained with the tank stored at an ambient temperature of 20°C, with air inlet of the duct at 7°C and all other
parameters in accordance with EN 16147.
**** According to EN 12102: ducted unit in/out 2m.
Summary of Contents for EHP-WH110
Page 6: ......
Page 7: ...7 1 INTRODUCTION...
Page 13: ...13 2 OVERVIEW OF THE UNIT...
Page 19: ...19 3 INSTALLATION...
Page 28: ...28...
Page 29: ...29 4 APPLIANCE OPERATION...
Page 38: ...38...
Page 39: ...39 5 MAINTENANCE...
Page 42: ...42...
Page 43: ...43 6 TECHNICAL INFORMATIONS...
Page 46: ...46 6 3 WIRING DIAGRAM Please refer to the wiring diagram sticked on the electric box...