Temperature controlling parameters: ST, F01,F02.
ST: is stop temperature that can be adjusted by SET key directly.
is
the
high
limit of setting temp.
These two parameters is used to limit the setting temp range in
order to avoid misoperation.
F01:
is
the
low
limit of setting temp.
F
02:
F
01≤
ST
≤
F
02
1.
2.1Heating status description
RINGDER
R
D R
RINGDER
RC-113M
Top Runner in Temperature Measuring and Controlling Industry
PID Temperature
Controller for Heating
User Manual
WEB: WWW.RINGDER.NET
Product Introduction
Xuzhou Ringder Electrical Equipment Co., Ltd.
Tel: 86-516-66656756 /87764448 FAX: 86-516-87769006
Website: http://www.ringder.net/indexen.asp;
http://ringder.en.alibaba.com/
Address: No. 385, Zhongshan North Road,Gulou District,Xuzhou City,Jiangsu Province, China.
E-mail:[email protected]
Product Introduction
This
model
is
specially
designed
for
elaborate
heating
system, which adopt high accuracy temperature sensor,
PID control, minimum
temperature inertia, very high
control accuracy(0.1C within normal temperature
period).
RC-113M PID temperature controller is widely applied to
various equipments and places that need to control
temperature accurately, such as incubator, Heating
equipment in the laboratory etc.
Technique
S
pecification
Anycontrol basic technique
:
specification list
Power supply
Rated power
≤
1
.
5W
Load capacity
Sensor type
NTC, 25
℃/
50K
Ω
Protection class
IP65
Work or storage
-10~60
℃,
RH
<
90%
no condensation
Temp. range
-40~110
℃
Environment
Comply with environmental standards
Wire length
Communication: 1Km,sensor:100m
220VAC
±
10% 50HZ
110VAC
±
10% 60HZ(optional)
≤
1500W; 110V/60HZ/750W;
≤
10A/220V/50HZ/2000W; 110V/60HZ/1000W(optional).
5A/220V/50HZ/
Function
and
Parameter
F
01
-10~
Set temp.
-10
F
0
2
Set temp.
~100
100
F
0
3
-7~7
0.0
Code
Function
Setting Range
Default
Unit
Set Low Limit
Set High Limit
Calibration
1.1.1 Temperature
calibration
1.1 Temperature
measurement
When
there is some difference between the measuring
temperature and the real temperature, the difference can be
calibrated by menu F3, and calibration method should follow
the below formula:F3=real temperature-measuring
temperature. Other functions will execute according to the
calibrated temperature value.
1.1.2 Sampling period
The sampling period of this model is 1 second fixedly, and other
sampling period can be customized.
1.2 Temperature control
The controller can PID adjust the power of the heater, and make
the temperature constant around the setting temp. During
25~42
℃,
the
accuracy can be
0.1℃
.
Product Size
Wiring Diagram
Load
Power
Sensor
Connect the wires strictly according to the diagram, the voltage
must within 220VAC
±
10%.
The current of the load must: inductive load or filament lamp
≤
10% of the current on the wiring diagram; resistive load
≤
60% of
the current on the wiring diagram.
Assembly and Installation
Warning
:
Relative
humidity
> 90 % ,
have
condensation
Strong vibration or struck
The places that temperature<
-10℃
or>
60℃;
Exposed to the continuous water mist spraying
;
The
places
that have inflammables and explosives
;
Exposed to the dust
;
The controller must be connected by trained electricians
according
to
the
user
manual strictly, and avoid installing in the
below environments:
Wireless electromagnetic interference or strong magnetic
fields(near to transmitting antenna or switch board room)
;
2.1 Assembly
Exposure to corrosive and pollution gas
(
for
example
:
the
gas,
smoke or salt fog that contain sulfur or ammonia
;
2.2 Please
install
the controller according to the following
Cut
out
a
hole
at
the
installing
postion:
7 1* 2 9
mm
Detach
the
slide
fasteners, and put the controller into the hole.
(
1st
step
,
Figure2
.
a
);
Install
the
faterners
;
(
2nd
step
,
Figure2
.
b
);
Figure
2 .
a
Figure
2.
b
After connecting the wire, install the waterproof tailgate
(
3rd
step
,
Figure2
.
c
);
Figure
2 .
c
How
to
disassemble
the
controller
from
the
hole
?
Firstly
disassemble the
tailgate, then press the
position
(
Figure2
.
d
)
sliding backwards to
disassemble the controler
;
Figure
2 .
d
User Interface & Button Function
3.1 Display Area
220V/50HZ
No
.
Meaning
Working
Status
/
/
/
1
2
3
Please
refer to
Display
Not Display
Flash
Set Indicator
Heat
Equipment
Alarm
Non set status
Work status
Set status
Stop status
Alarm status
Non alarm status