Microcomputer Temperature Controller User Manual 

Model:RC-112E 

The product adopts the latest electronic technique with LED display, which learn from the 

advantages and experience of stand-alone edition temperature controllers domestically 

and overseas. It is the most economical product with simple operation, stable performance, 

small size and intelligent control, cool and heat shift functions, which applies to various 

refrigeration and heating places and equipments. 

Temperature measure range:

  - 4 0 ~ 9 9 ' C 

Resolution: 1 

Accuracy:

 ±1*0 

Power supply: 220VAC/110VAC/12V±10%,50/60HZ 

Input: one NTC sensor 

Output: one relay 10A/220VAC 

Ambient requirements: temperature: -10~60°C; humidity:  2 0 - 8 5 % (No condensate) 

Cut out size: 71mmx29mm 
Consumption: 

E

H

I

WORK indicator: means the output load is in working status; Normally on means work: 
flash means delay: Off means not work. 

SET indicator: means set status, Normally on means work; Off means not work. 

Operation Instruction 

Buttons: SET , UP ^ 

1. Temperature setting: 

, DOWN ^ , POWER (J; 

Summary of Contents for RC-112E

Page 1: ...all size and intelligent control cool and heat shift functions which applies to various refrigeration and heating places and equipments Temperature measure range 40 99 C Resolution 1 Accuracy 1 0 Power supply 220VAC 110VAC 12V 10 50 60HZ Input one NTC sensor Output one relay 10A 220VAC Ambient requirements temperature 10 60 C humidity 20 85 No condensate Cut out size 71mmx29mm Consumption E H I B ...

Page 2: ...ment press SET to the next parameter use the same method to set the rest parameters When finishing press on SET for 3 seconds or without any operation for 15 seconds the controller will return to normal working status and save the adjustments 3 Switch on and off In the off status press POWER button to switch on in the on status press POWER button 5 seconds to switch off the controller Function Men...

Page 3: ...e activated after the delay time If the time period between the previous stop and this starts is longer than the delay time the output will be activated immediately if it is shorter than the delay time the output will be activated after the delay time The delay time is calculated from the previous output stop 4 High and low temperature limit HS and LS can set the high and low limit of the setting ...

Page 4: ...le place avoid crash The device cannot be placed with dripping or water and keep away from the electromagnetic interference of the electrical apparatus 3 In order to prevent the interference of high frequency the sensors and low voltage lines cannot parallel and be bundled up with high voltage line The diameter of the high voltage wire must be between 0 75 mm and 1 5mm 4 If the device is disturbed...