background image

1

Motion Detector 2nd Generation  

Z-Wave™ Technical Manual

Summary of Contents for Alarm Motion Detector v2

Page 1: ...1 Motion Detector 2nd Generation Z Wave Technical Manual ...

Page 2: ...or features and functions within the Ring app Notes 1 This product can be operated in any Z Wave network with other Z Wave certified devices from other manufacturers All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network 2 SmartStart enabled products can be added into a Z Wave network by scanning the Z Wave QR Code present on t...

Page 3: ...ouble sided tape peel the backing and attach the Motion Detector to the mounting location Note Leave in of space free on the top side to ensure you can slide open the case when it s time to change the batteries This product can be operated in any Z Wave network with other Z Wave certified devices from other manufacturers All mains operated nodes within the network will act as repeaters regardless ...

Page 4: ...4 ...

Page 5: ...ic Inclusion Steps Classic Inclusion should be used if the controller does not support SmartStart 1 Initiate add flow for Security Devices in the Ring mobile application Follow the guided add flow instructions provided in the Ring mobile application 2 Select add manually and enter the 5 digit DSK PIN found on the package of the Ring Alarm Motion Detector or the 5 digit DSK PIN found under the QR c...

Page 6: ...ion Detector Factory Reset Factory Default Instructions 1 To restore Ring Alarm Motion Detector to factory default settings locate the pinhole reset button on the device This is found inside the battery compartment on the back of the device after removing the back bracket 2 Using a paperclip or similar object insert it into the pinhole press and hold the button down for 10 seconds 3 The device wil...

Page 7: ...annel Association 3 Highest granted Powerlevel 1 Highest granted Security 2 1 none Supervision 1 none Transport Service 2 none Version 3 Highest granted Z Wave Plus Info 2 none Notification 8 Highest granted Wake Up 2 Highest granted Configuration 4 Highest granted Battery 2 Highest granted Association Command Class Group Identifier Max Nodes Description 1 Lifeline 0x05 1 Notification Report a See...

Page 8: ...ications on the device 0 Don t show green 1 Show green after Supervision Report Intrusion Fault 2 Show green after Supervision Report both Intrusion and Intrusion clear 1 1 0x01 0 0x00 2 0x01 enum 5 The number of milliseconds waiting for a Supervisory Report response to a Supervisory Get encapsulated command from the sensor before attempting a retry 2 1500 0x5DC 500 0x1F4 5000 0x1388 0x01 Unsigned...

Page 9: ...ng Value for Soft Fault 1 Lifeline Software Fault SDK Notification Report Type System 0x09 State Value 0x04 System Software Failure State Parameter Value 0xA9 SDK Value for Soft Fault 1 Lifeline Pin Reset soft reset Notification Report Type System 0x09 State Value 0x04 System Software Failure State Parameter Value 0xAB 1 Lifeline Software Reset Not triggered by failure Notification Report Type Sys...

Page 10: ...allation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circu...

Page 11: ... could void the user s authority to operate the equipment AVERTISSEMENT Tout changement ou modification à cet appareil qui n a pas fait l objet d une autorisation expresse par la partie responsable de sa conformité pourrait annuler le droit pour l utilisateur d opérer l équipement CAUTION To reduce the risk of electrical shock DO NOT open the unit There are no user serviceable parts inside the uni...

Reviews: