Power

Source

Pro

User Manual

RINV1000

RINV2000

4

L209

Protective features
Low battery alarm

- An alarm will sound when the voltage from the battery drops to 10.5 volts DC. This indicates

that the battery the PowerSource is connected to will require recharging. (If connected to a vehicle battery,
starting the vehicle engine should be sufficient) The Powersource will automatically shutdown if its voltage is
allowed to drop to 9.5 volts DC or below.

Over voltage protection

- The PowerSource will automatically shutdown if the input voltage exceeds 15 volts DC.

Reverse polarity protection

- Reverse polarity (incorrect battery connection) may result in the blowing of the

internal blade fuses. If this occurs immediately, disconnect the battery. The internal blade fuses will need to be
checked by a qualified electrician if the PowerSource does not continue to work.

Overload protection

- The PowerSource will automatically shut down if the continuous power draw exceeds its

maximum rating of the PowerSource.

Temperature protection

- If the temperature of the internal heat sink reaches >65oC the Powersource will shut

down automatically. Allow the PowerSource to cool before using again.

Troubleshooting guide

Problem

Possible Cause

Suggested Remedy

Low output voltage

PowerSource is overloaded

Reduce load, not exceeding maximum rating

Low battery alarm on all the time

Inadequate power or excessive voltage drop

Check connections from battery
to PowerSource

Poor battery condition

Replace battery

No Power output

PowerSource not fully warmed up

Turn the PowerSource switch on and off
repeatedly until the appliance has started.

Internal fuses have blown

Fuse replacement (qualified electrician only)

PowerSource in thermal shutdown condition

Allow to cool (10 Minutes)

Low battery voltage

Charge or replace battery

Specifications

PowerSource Model

RINV1000

RINV2000

Max. Continuous power (Watts) 

1

/

2

hour only

1000w 

2000w 

Continuous Power 

800w

1600w

Peak Power (Watts) 0.01 Seconds

2000w

4000w

Standby current (AMPS)

< 0.5A

< 0.8A

Waveform

Modified sine wave

Modified sine wave

Efficiency 

Approximately 90 %

Approximately 90 %

Input Voltage Range

10v – 15v DC

10v – 15v DC

AC Socket

3 Pin mains 

3 Pin mains 

Fuse

30 amps (x 4)

30 amps (x 8)

Percentage of battery power converted to mains voltage power.

‘e’ & ‘CE’ approved

Distributed by:

Ring Automotive  Gelderd Road, Leeds LS12 6NB
Tel: +44 (0)113 276 7676  Fax: +44 (0)113 231 0266  
Email: [email protected]