Page 1: ...DNA934P Telephone Dialer Recorder Ring Communications Inc Ring Master ...

Page 2: ......

Page 3: ...ION 7 J1 Connector 7 J3 Connector 8 Front Panel Switches and Indicators 8 Resetting Battery RAM 9 CONFIGURATION 10 Type fonts 10 Prompt 10 Error Handling 10 HELP COMMANDS 11 Telephone Numbers 11 LINE SUPERVISION 13 RECORDED MESSAGES 14 RM5000EX CB901EX CONFIGURATION 15 CB901CA CONFIGURATION 16 ...

Page 4: ......

Page 5: ...r on the list is dialed If all 4 numbers are busy or no one answers then the dialer will continue to dial all 4 numbers until one of the numbers answers When the dialed telephone answers a recorded message is played to that telephone This message will identify the name and address of the building where the call is coming from Following this message the called party will receive a message identifyi...

Page 6: ...DNA934P Telephone Dialer with Recorder April 2017 Page 6 Ring Master ...

Page 7: ...ack with screw terminals KB171 for external connections Connect the external jack to J1 using a modular cable BF640A Pin Description 1 No Connection 2 power input 24 VDC 3 Data 4 Intercom audio b 5 Intercom audio a 6 Data 7 power input 8 External Alarm Connect Intercom Audio 24VDC and RS485 Data to the Central exchange using 3 twisted pair cable unshielded Page 7 Ring Master Illustration 1 DNA934P...

Page 8: ...lay Connect the telephone line to pin 3 4 twisted pair Front Panel Switches and Indicators Indicators RUN Processor is active MASTER The Master of the RS485 Network will have this LED on TX Transmit Data to the Network RX Receive Data from the Network RM ON Intercom port is active RING IN Telephone line is ringing CALL PROGRESS Audio detected on the telephone line OFF HOOK Telephone line off hook ...

Page 9: ...onference Handset 4 Interface at remote Conference Handset 5 OFF 6 OFF 7 OFF 8 Telephone Line Supervision Resetting Battery RAM When the system is first installed the DNA934P must be reset before any configuration is done Procedure 1 Set all 8 DIP switches in SW2 to OFF 2 Push and release RESET switch 3 Wait for MASTER LED to start blinking reset complete 4 Set Network address 5 Push and release R...

Page 10: ...back up memory in the DNA934P When the system is first installed the DNA934P must be reset before any configuration is done see page 4 Type fonts boldface type indicates user input courier font indicates output Prompt Angle brackets enclose input parameters Hexadecimal value Error Handling Misspelled command input will give the following message Unknown Command Parameter errors will print ERROR th...

Page 11: ...e SAK Set Answer Key STK Set Terminate Key Telephone Numbers Up to 4 telephone numbers can be programmed in speed dial list PROGRAMMING The following commands are used SSD Set Speed Dial Number SRT Set Ringing Timer SMC Set Message Counter software 2010 02 08 SAK Set Answer Key software 2013 11 25 STK Set Terminate Key software 2015 04 28 LSD List Speed Dial Numbers Example Program 631 585 7418 as...

Page 12: ...ore dialing the number To insert a wait for dial tone use the option D DNA934P SSD 1 9D6315857418 choice 1 dial 9 wait for dial tone then dialing the number To change how long time it should ring for a telephone number Default is 30 seconds 5 x 6seconds DNA934P SRT 1 4 choice 1 ring for 24 seconds 4x6 then call choice 2 To change how many times the recorded message is played for each choice Defaul...

Page 13: ...s OK then wait for dial tone If dial tone is detected then dial DTMF 1 The Central Office detects the DTMF tone and will remove the dial tone If the dial tone does not stop then there s a dialing problem Go On hook and detect that the loop current stopped Any fault detected with the telephone line will activate the Fault condition and the telephone line is then tested every 10 seconds until the fa...

Page 14: ...o reject this call hang up To listen to a message Disconnect Telephone Line From a intercom master station dial the extension of the DNA934P From the PC enter the command DNA934P P 10 Message number 10 will now be played to the intercom speaker To change a message Disconnect Telephone Line From a intercom master station dial the extension of the DNA934P From the PC enter the command DNA934P R 10 S...

Page 15: ...programmed in choices 1 4 Example Adding the DNA934P to an existing system Connect voice to call number 30 Connect data to RS485 using Network address 0C Calls are to transfer from intercom 10 to the DNA934P if not answered by intercom 10 within 30 seconds Programming commands that need to be added to RM5000EX CB901EX EX500 SDT 30 2 Set device type ICM EX500 SPT 30 11 Set privilege silent ring EX5...

Page 16: ...ension When the DNA934P receives a transferred call it will dial the telephone numbers that are programmed in choices 1 4 Example Adding the DNA934P to an existing system Connect voice to call number 130 subscriber address 1E Connect data to RS485 using Network address 0C Calls are to transfer from intercom 100 to the DNA934P if not answered by intercom 100 within 30 seconds Programming commands t...