32
(4) PW/TR light flashing
① System trouble 「E-00」
<Cause and action>
・Memory trouble inside of indicator/alarm unit.
Contact our nearest agent or RIKEN KEIKI.
② Sensor connection trouble 「E-01」
<Cause and action>
・Non-connection of sensor, contact failure of connector and disconnection of sensor cable.
・Check “whether sensor is connected” or “the sensor cable connector is connected to the sensor.
If can not be recovered, contact our nearest agent or RIKEN KEIKI.
(5) Fuse disconnection
<Performance>
・This unit can not work.
<Cause and action>
・The trouble of this unit or trouble of external power source can be considered. Search this cause
and after taking its measures, replace the fuse with the designate one.
*NOTE
The fuse rating for this unit is “250V/1A T”.